HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Potential biomarker proteins for aspiration pneumonia detected by shotgun proteomics using buccal mucosa samples: a cross-sectional case-control study.

AbstractBACKGROUND:
Aspiration pneumonia (AP), which is a major cause of death in the elderly, does present with typical symptoms in the early stages of onset, thus it is difficult to detect and treat at an early stage. In this study, we identified biomarkers that are useful for the detection of AP and focused on salivary proteins, which may be collected non-invasively. Because expectorating saliva is often difficult for elderly people, we collected salivary proteins from the buccal mucosa.
METHODS:
We collected samples from the buccal mucosa of six patients with AP and six control patients (no AP) in an acute-care hospital. Following protein precipitation using trichloroacetic acid and washing with acetone, the samples were analyzed by liquid chromatography and tandem mass spectrometry (LC-MS/MS). We also determined the levels of cytokines and chemokines in non-precipitated samples from buccal mucosa.
RESULTS:
Comparative quantitative analysis of LC-MS/MS spectra revealed 55 highly (P values < 0.10) abundant proteins with high FDR confidence (q values < 0.01) and high coverage (> 50%) in the AP group compared with the control group. Among the 55 proteins, the protein abundances of four proteins (protein S100-A7A, eukaryotic translation initiation factor 1, Serpin B4, and peptidoglycan recognition protein 1) in the AP group showed a negative correlation with the time post-onset; these proteins are promising AP biomarker candidates. In addition, the abundance of C-reactive protein (CRP) in oral samples was highly correlated with serum CRP levels, suggesting that oral CRP levels may be used as a surrogate to predict serum CRP in AP patients. A multiplex cytokine/chemokine assay revealed that MCP-1 tended to be low, indicating unresponsiveness of MCP-1 and its downstream immune pathways in AP.
CONCLUSION:
Our findings suggest that oral salivary proteins, which are obtained non-invasively, can be utilized for the detection of AP.
AuthorsKohei Ogura, Maho Endo, Takashi Hase, Hitomi Negami, Kohsuke Tsuchiya, Takumi Nishiuchi, Takeshi Suzuki, Kazuhiro Ogai, Hiromi Sanada, Shigefumi Okamoto, Junko Sugama
JournalClinical proteomics (Clin Proteomics) Vol. 20 Issue 1 Pg. 9 (Mar 09 2023) ISSN: 1542-6416 [Print] England
PMID36894881 (Publication Type: Journal Article)
Copyright© 2023. The Author(s).

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: