HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Performance of the Kleihauer Betke test in the prediction of neonatal anemia.

AbstractOBJECTIVES:
The aim of this study was to correlate antenatal Kleihauer (KT) test results with fetal hemoglobin at birth to find a threshold for predicting severe fetal anemia. The secondary objectives were to assess the impact of KT on obstetric management and to study the correlation between the middle cerebral artery peack systolic velocity and fetal anemia.
RESULTS:
One thousand forty-six KT were positive over the 10-year period, but only 147 were included from 88 patients, of which 17 fetuses were anemic. Demographic and obstetric characteristics were similar between anemic and non-anemic groups. As regards new-born, there was a higher risk of prematurity among anemic as long as a lower birth rate in accordance. While a negative correlation was observed between KT and hemoglobin at birth, no KT upper threshold could be found that was both sensitive and specific. In addition, there was no case of fetal anemia when KT was repeated, even though it increased. KT showed little usefulness in obstetrics management to help improving neonatal care for anemia. Conversely, the MCA PSV demonstrated good performance in this matter and the ROC curve area was 0.91 (figure).
DISCUSSION:
Feto-maternal hemorrhage is a rare but grave pathology which could lead to anemia. The most common clinical sign is reduced fetal movement and it was the main indication to perform a KT. Cardiotocography patterns suggestive of anemia are sinusoidal, micro-oscillatory and non-reactive monitoring. Ultrasound features were polyhydramnios, hydrop fetalis and increased MCA peack systolic velocity. KT was correlated with MCA PSV and with hemoglobin level at birth. However, the latter showed a better diagnostic performance. MCA PSV measurement is a powerful test to screen for fetal anemia, and should be part of the regular training of obstetricians. Indeed, this technic gives immediate and reliable results, while those of KT are delayed.
CONCLUSION:
The KT should not be used as a tool to screen for fetal anemia but rather as a test to explain a fetal anemia. However, the MCA PSV is reliable in this matter and give immediate result, thus obstetrician should be trained to routinely perform it.
AuthorsPauline Bataille, Laurent Petit, Norbert Winer
JournalThe journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians (J Matern Fetal Neonatal Med) Vol. 35 Issue 19 Pg. 3670-3676 (Oct 2022) ISSN: 1476-4954 [Electronic] England
PMID33106065 (Publication Type: Journal Article)
Chemical References
  • Hemoglobins
Topics
  • Anemia (diagnosis)
  • Anemia, Neonatal (diagnosis)
  • Blood Flow Velocity
  • Female
  • Fetal Diseases (diagnosis)
  • Hemoglobins
  • Humans
  • Infant, Newborn
  • Middle Cerebral Artery (diagnostic imaging)
  • Pregnancy
  • Ultrasonography, Prenatal

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: