HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

An Umeclidinium membrane sensor; Two-step optimization strategy for improved responses.

Abstract
In the scientific context of membrane sensors and improved experimentation, we devised an experimentally designed protocol for sensor optimization. Two-step strategy was implemented for Umeclidinium bromide (UMEC) analysis which is a novel quinuclidine-based muscarinic antagonist used for maintenance treatment of symptoms accompanied with chronic obstructive pulmonary disease. In the first place, membrane components were screened for ideal ion exchanger, ionophore and plasticizer using three categorical factors at three levels in Taguchi design. Secondly, experimentally designed optimization was followed in order to tune the sensor up for finest responses. Twelve experiments were randomly carried out in a continuous factor design. Nernstian response, detection limit and selectivity were assigned as responses in these designs. The optimized membrane sensor contained tetrakis-[3,5-bis(trifluoro- methyl)phenyl] borate (0.44wt%) and calix[6]arene (0.43wt%) in 50.00% PVC plasticized with 49.13wt% 2-ni-tro-phenyl octylether. This sensor, along with an optimum concentration of inner filling solution (2×10-4molL-1 UMEC) and 2h of soaking time, attained the design objectives. Nernstian response approached 59.7mV/decade and detection limit decreased by about two order of magnitude (8×10-8mol L-1) through this optimization protocol. The proposed sensor was validated for UMEC determination in its linear range (3.16×10-7 -1×10-3mol L-1) and challenged for selective discrimination of other congeners and inorganic cations. Results of INCRUSE ELLIPTA® inhalation powder analyses obtained from the proposed sensor and manufacturer's UPLC were statistically compared. Moreover the proposed sensor was successfully used for the determination of UMEC in plasma samples.
AuthorsAli M Yehia, Hany H Monir
JournalTalanta (Talanta) Vol. 172 Pg. 61-67 (Sep 01 2017) ISSN: 1873-3573 [Electronic] Netherlands
PMID28602304 (Publication Type: Journal Article)
CopyrightCopyright © 2017 Elsevier B.V. All rights reserved.
Chemical References
  • GSK573719
  • Membranes, Artificial
  • Quinuclidines
Topics
  • Electrochemistry (instrumentation)
  • Electrodes
  • Limit of Detection
  • Membranes, Artificial
  • Quinuclidines (chemistry)

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: