[Contact hypersensitivity to Kathon CG. Apropos of 35 cases among 977 tested subjects].

Abstract
Kathon CG (Rohm and Haas) is a mixture of two isothiazolinones: chloromethylisothiazolinone and methylisothiazolinone. It is widely used in aqueous solution as antimicrobial agent in cosmetics (CG means cosmetic grade) instead of parabens. Routine testing is effected with Kathon CG in aqueous solution at 100 ppm (Trolab) in finn chamber tests on scanpor (ICDRG directives). Between September 1987 and September 1989, 977 patients (538 women, 439 men) referred for suspected contact allergy were tested. Thirty-five patients (77 p. 100 of whom were young women) with a history of allergy to cosmetics were found to be positive. Face, hands or both were involved in 15, 7 and 9 cases respectively, and a lupus-like reaction was observed in one patient. Our results (frequency: 3.6 p. 100) were compared with previously published results ranging from 0.67 p. 100 to 16.1 p. 100 (tables IV and V). Such wide variations can be explained by different selections of patients, different uses of cosmetics and lack of standardization in testing. Patch tests were strongly positive (quoted + +) in all cases. None of the irritant effects previously reported (3, 8, 28) was detected. In a control study carried out two months later, diluted patch tests (100, 50, 25, 15 and 7.5 ppm) were performed in 15 patients and were positive in 11 of them: 5 at 25 ppm, 1 at 15 ppm and 5 only at 100 ppm. Contrary to previous suggestions (7, 28, 36), there was no correlation between allergenic potential and minimal concentration, so that the "no response concentration" concept could not be confirmed.(ABSTRACT TRUNCATED AT 250 WORDS)
AuthorsG Ledieu, P Martin, P Thomas
JournalAnnales de dermatologie et de venereologie (Ann Dermatol Venereol) Vol. 118 Issue 3 Pg. 181-9 ( 1991) ISSN: 0151-9638 [Print] France
Vernacular TitleL'allergie de contact au Kathon CG. A propos de 35 cas sur 977 sujets testés.
PMID2064280 (Publication Type: Clinical Trial, English Abstract, Journal Article, Review)
Chemical References
  • Adhesives
  • Cosmetics
  • Mutagens
  • Preservatives, Pharmaceutical
  • Thiazoles
  • Kathon 886
Topics
  • Adhesives (adverse effects)
  • Adult
  • Aged
  • Cosmetics (adverse effects, chemistry)
  • Dermatitis, Contact (epidemiology, immunology)
  • Drug Hypersensitivity (immunology)
  • Female
  • Household Products (adverse effects)
  • Humans
  • Male
  • Middle Aged
  • Mutagens (adverse effects, immunology)
  • Patch Tests
  • Preservatives, Pharmaceutical (adverse effects)
  • Thiazoles (adverse effects, immunology)

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: