Renal tolerance of a neutral gadolinium chelate (gadobutrol) in patients with chronic renal failure: results of a randomized study.

AbstractPURPOSE:
To assess the renal tolerance of 1.0 mol/L gadobutrol as an electrically neutral contrast agent at magnetic resonance (MR) imaging in patients with impaired renal function.
MATERIALS AND METHODS:
Twenty-one patients with impaired renal function were enrolled in this prospective randomized study and classified into two subgroups according to their creatinine clearance: group 1 (n = 12), less than 80 mL/min (<1.33 mL/sec) and greater than 30 mL/min (>0.50 mL/sec); group 2 (n = 9), less than 30 mL/min (<0.50 mL/sec) and not requiring dialysis. Gadobutrol (1.0 mol/L) was injected intravenously at randomly assigned doses of either 0.1 or 0.3 mmol per kilogram of body weight. Changes in vital signs, clinical chemistry, and urinalysis results, including creatinine clearance, were monitored before, at 6 hours, and then every 24 hours until 72 hours (group 1) or 120 hours (group 2) after intravenous injection of gadobutrol. Hematologic results were checked every other day.
RESULTS:
No serious adverse event occurred, and no clinically relevant changes in vital signs, hematologic results, clinical chemistry, or urinalysis results were detected in the observation period. Markers for glomerular filtration (creatinine, cystatin C, beta2-microglobulin, creatinine clearance) and tubular function (N-acetyl-beta-D-glucosaminidase, alpha1-microglobulin) were unaffected by gadobutrol in both groups.
CONCLUSION:
Gadobutrol did not affect renal function and, therefore, proved to be a safe MR contrast agent in patients with impaired renal function. Even in patients with marginal excretory function (creatinine clearance, <30 mL/min [<0.50 mL/sec]), prehydration or treatment with diuretics or hemodialysis are not required after the administration of gadobutrol.
AuthorsB Tombach, C Bremer, P Reimer, K Kisters, R M Schaefer, V Geens, W Heindel
JournalRadiology (Radiology) Vol. 218 Issue 3 Pg. 651-7 (Mar 2001) ISSN: 0033-8419 [Print] United States
PMID11230635 (Publication Type: Clinical Trial, Journal Article, Randomized Controlled Trial)
Chemical References
  • Contrast Media
  • Organometallic Compounds
  • gadobutrol
Topics
  • Adult
  • Aged
  • Contrast Media (administration & dosage, toxicity)
  • Female
  • Humans
  • Injections, Intravenous
  • Kidney (drug effects)
  • Kidney Failure, Chronic (physiopathology)
  • Male
  • Middle Aged
  • Organometallic Compounds (administration & dosage, toxicity)
  • Prospective Studies

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: