HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Long-Term Wear-Related Complications of Cross-Linked Versus Conventional Polyethylene After Total Hip Arthroplasty: A Meta-Analysis.

AbstractBACKGROUND:
Highly cross-linked polyethylene (HXLPE) liners have been developed to address the wear-related problems associated with conventional polyethylene (CPE) such as osteolysis or aseptic loosening in total hip arthroplasty (THA). In this systematic meta-analysis, we compared the long-term efficacy in preventing radiological osteolysis and revision surgery between HXLPE and CPE.
METHODS:
We included 14 studies that compared HXLPE and CPE reporting the incidence of wear-related complications with a minimum follow-up of 10 years. We investigated 5 wear-related complications: osteolysis, excessive wear, linear wear rate, revision surgery due to wear, and progress of osteolysis/aseptic loosening. We conducted a pair-wise meta-analysis to estimate odds ratio (OR) and a proportional meta-analysis to estimate the incidence of each complication.
RESULTS:
Among 1,175 THAs, 220 osteolysis and 78 wear-related revisions were detected. The use of HXLPE reduced the risk of overall osteolysis (OR 0.30; P = .001), excessive wear (OR 0.10; P < .001), linear wear rate (weighted mean difference 0.09; P < .001), the risk of overall wear-related revisions (OR 0.06; P < .001), and revisions due to aseptic loosening (OR 0.23; P = .015). As per the proportional meta-analysis, the pooled prevalence of osteolysis, excessive wear, and the overall wear-related revision rate were 14%, 8%, and 3% in HXLPE and 25%, 33%, and 20% in CPE, respectively.
CONCLUSION:
The current evidence shows that HXLPE dramatically reduced the rate of osteolysis and wear-related revision surgery. However, as polyethylene wear and osteolysis still lead to revision surgery, ongoing clinical and retrieval studies are required to analyze long-term outcomes.
AuthorsByung-Ho Yoon, Jung-Wee Park, Young-Kyun Lee, Kyung-Hoi Koo, Chong Bum Chang
JournalThe Journal of arthroplasty (J Arthroplasty) Vol. 37 Issue 11 Pg. 2308-2315.e2 (11 2022) ISSN: 1532-8406 [Electronic] United States
PMID35568139 (Publication Type: Journal Article, Meta-Analysis, Research Support, Non-U.S. Gov't)
CopyrightCopyright © 2022 Elsevier Inc. All rights reserved.
Chemical References
  • Polyethylene
Topics
  • Arthroplasty, Replacement, Hip (adverse effects)
  • Follow-Up Studies
  • Hip Prosthesis (adverse effects)
  • Humans
  • Osteolysis (epidemiology, etiology, prevention & control)
  • Polyethylene
  • Prosthesis Design
  • Prosthesis Failure

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: