HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Optimal 68Ga-PSMA and 18F-PSMA PET window levelling for gross tumour volume delineation in primary prostate cancer.

AbstractPURPOSE:
This study proposes optimal tracer-specific threshold-based window levels for PSMA PET-based intraprostatic gross tumour volume (GTV) contouring to reduce interobserver delineation variability.
METHODS:
Nine 68Ga-PSMA-11 and nine 18F-PSMA-1007 PET scans including GTV delineations of four expert teams (GTVmanual) and a majority-voted GTV (GTVmajority) were assessed with respect to a registered histopathological GTV (GTVhisto) as the gold standard reference. The standard uptake values (SUVs) per voxel were converted to a percentage (SUV%) relative to the SUVmax. The statistically optimised SUV% threshold (SOST) was defined as those that maximises accuracy for threshold-based contouring. A leave-one-out cross-validation receiver operating characteristic (ROC) curve analysis was performed to determine the SOST for each tracer. The SOST analysis was performed twice, first using the GTVhisto contour as training structure (GTVSOST-H) and second using the GTVmajority contour as training structure (GTVSOST-MA) to correct for any limited misregistration. The accuracy of both GTVSOST-H and GTVSOST-MA was calculated relative to GTVhisto in the 'leave-one-out' patient of each fold and compared with the accuracy of GTVmanual.
RESULTS:
ROC curve analysis for 68Ga-PSMA-11 PET revealed a median threshold of 25 SUV% (range, 22-27 SUV%) and 41 SUV% (40-43 SUV%) for GTVSOST-H and GTVSOST-MA, respectively. For 18F-PSMA-1007 PET, a median threshold of 42 SUV% (39-45 SUV%) for GTVSOST-H and 44 SUV% (42-45 SUV%) for GTVSOST-MA was found. A significant pairwise difference was observed when comparing the accuracy of the GTVSOST-H contours with the median accuracy of the GTVmanual contours (median, - 2.5%; IQR, - 26.5-0.2%; p = 0.020), whereas no significant pairwise difference was found for the GTVSOST-MA contours (median, - 0.3%; IQR, - 4.4-0.6%; p = 0.199).
CONCLUSIONS:
Threshold-based contouring using GTVmajority-trained SOSTs achieves an accuracy comparable with manual contours in delineating GTVhisto. The median SOSTs of 41 SUV% for 68Ga-PSMA-11 PET and 44 SUV% for 18F-PSMA-1007 PET form a base for tracer-specific window levelling.
TRIAL REGISTRATION:
Clinicaltrials.gov ; NCT03327675; 31-10-2017.
AuthorsCédric Draulans, Robin De Roover, Uulke A van der Heide, Linda Kerkmeijer, Robert J Smeenk, Floris Pos, Wouter V Vogel, James Nagarajah, Marcel Janssen, Sofie Isebaert, Frederik Maes, Cindy Mai, Raymond Oyen, Steven Joniau, Martina Kunze-Busch, Karolien Goffin, Karin Haustermans
JournalEuropean journal of nuclear medicine and molecular imaging (Eur J Nucl Med Mol Imaging) Vol. 48 Issue 4 Pg. 1211-1218 (04 2021) ISSN: 1619-7089 [Electronic] Germany
PMID33025093 (Publication Type: Journal Article, Research Support, Non-U.S. Gov't)
Chemical References
  • Gallium Isotopes
  • Gallium Radioisotopes
  • Oligopeptides
  • gallium 68 PSMA-11
  • Edetic Acid
Topics
  • Edetic Acid (analogs & derivatives)
  • Gallium Isotopes
  • Gallium Radioisotopes
  • Humans
  • Male
  • Oligopeptides
  • Positron Emission Tomography Computed Tomography
  • Prostatic Neoplasms (diagnostic imaging)
  • Tumor Burden

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: