The predictive performance of propofol target-controlled infusion during robotic-assisted laparoscopic prostatectomy with CO2 pneumoperitoneum in the head-down position.

AbstractPURPOSE:
Propofol clearance can be reduced when cardiac output (CO) is decreased. This clearance reduction may alter the pharmacokinetics of propofol and worsen the predictive performance of target-controlled infusion (TCI) of propofol. The head-down position (HDP) and CO2 pneumoperitoneum, which are required for robotic-assisted laparoscopic prostatectomy (RALP), may cause changes in CO. We investigated the predictive performance of propofol TCI during CO2 pneumoperitoneum in patients who underwent RALP in the HDP.
METHODS:
Fifteen male patients received propofol TCI using the Diprifusor model. Propofol concentrations were measured at seven time points: (T1) 15 min after anesthesia induction; (T2) before the insufflation; (T3, T4, and T5) 15, 60, and 90 min, respectively, after insufflation in the HDP; (T6) before the release of pneumoperitoneum in the HDP; and (T7) 15 min after the release of pneumoperitoneum in the supine position. Cardiac index (CI) was assessed using an arterial pulse contour CO monitor. The predictive performance of propofol TCI was evaluated by calculating the performance errors (PE) in propofol concentrations for each data point. The relationship between CI and PE was examined. Median PE (MDPE) and median absolute PE (MDAPE) were calculated as measures of bias and accuracy, respectively.
RESULTS:
A total of 104 blood samples were analyzed. There was significantly negative correlation between CI and PE. The predictive performance of propofol TCI during pneumoperitoneum in the HDP was acceptable (MDPE = - 1.5% and MDAPE = 18.8%).
CONCLUSION:
The predictive performance of propofol TCI during RALP with CO2 pneumoperitoneum in the HDP was acceptable.
AuthorsTomoko Ogawa, Shinju Obara, Mitsue Akino, Chie Hanayama, Hidemi Ishido, Masahiro Murakawa
JournalJournal of anesthesia (J Anesth) Vol. 34 Issue 3 Pg. 397-403 (06 2020) ISSN: 1438-8359 [Electronic] Japan
PMID32222907 (Publication Type: Journal Article)
Chemical References
  • Anesthetics, Intravenous
  • Carbon Dioxide
  • Propofol
Topics
  • Anesthetics, Intravenous
  • Carbon Dioxide
  • Cardiac Output
  • Humans
  • Insufflation
  • Laparoscopy
  • Male
  • Pneumoperitoneum
  • Propofol
  • Prostatectomy (methods)
  • Robotic Surgical Procedures

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: