Dosimetric comparison of single-beam multi-arc and 2-beam multi-arc VMAT optimization in the Monaco treatment planning system.

Abstract
The purpose of this study was to evaluate the dosimetric and practical effects of the Monaco treatment planning system "max arcs-per-beam" optimization parameter in pelvic radiotherapy treatments. We selected for this study a total of 17 previously treated patients with a range of pelvic disease sites including prostate (9), bladder (1), uterus (3), rectum (3), and cervix (1). For each patient, 2 plans were generated, one using an arc-per-beam setting of "1" and another with an arc-per-beam setting of "2" using the volumes and constraints established from the initial clinical treatments. All constraints and dose coverage objects were kept the same between plans, and all plans were normalized to 99.7% to ensure 100% of the planning target volume (PTV) received 95% of the prescription dose. Plans were evaluated for PTV conformity, homogeneity, number of monitor units, number of control points, and overall plan acceptability. Treatment delivery time, patient-specific quality assurance procedures, and the impact on clinical workflow were also assessed. We found that for complex-shaped target volumes (small central volumes with extending arms to cover nodal regions), the use of 2 arc-per-beam (2APB) parameter setting achieved significantly lower average dose-volume histogram values for the rectum V20 (p = 0.0012) and bladder V30 (p = 0.0036) while meeting the high dose target constraints. For simple PTV shapes, we found reduced monitor units (13.47%, p = 0.0009) and control points (8.77%, p = 0.0004) using 2APB planning. In addition, we found a beam delivery time reduction of approximately 25%. In summary, the dosimetric benefit, although moderate, was improved over a 1APB setting for complex PTV, and equivalent in other cases. The overall reduced delivery time suggests that the use of mulitple arcs per beam could lead to reduced patient-on-table time, increased clinical throughput, and reduced medical physics quality assurance effort.
AuthorsAlan M Kalet, Hannah L Richardson, Darrin A Nikolaisen, Ning Cao, Myra A Lavilla, Claire Dempsey, Juergen Meyer, Wui-Jin Koh, Kenneth J Russell
JournalMedical dosimetry : official journal of the American Association of Medical Dosimetrists (Med Dosim) 2017 Summer Vol. 42 Issue 2 Pg. 122-125 ISSN: 1873-4022 [Electronic] United States
PMID28476456 (Publication Type: Comparative Study, Evaluation Study, Journal Article)
CopyrightCopyright © 2017 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Topics
  • Humans
  • Pelvic Neoplasms (radiotherapy)
  • Radiotherapy Dosage
  • Radiotherapy Planning, Computer-Assisted (methods)
  • Radiotherapy, Intensity-Modulated (methods)
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Software
  • Treatment Outcome