HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Left ventricular ejection fraction as criterion for implantation of an implantable cardioverter-defibrillator in heart failure patients undergoing surgical left ventricular reconstruction.

AbstractBACKGROUND:
Besides implantation of an implantable cardioverter-defibrillator (ICD), a proportion of patients with left ventricular (LV) dysfunction due to ischemic cardiomyopathy are potential candidates for surgical LV reconstruction (Dor procedure), which changes LV ejection fraction (LVEF) considerably. In these patients, LVEF as selection criterium for ICD implantation may be difficult. This study aimed to determine the value of LVEF as criterium for ICD implantation in heart failure patients undergoing surgical LV reconstruction.
METHODS:
Consecutive patients with end-stage heart failure who underwent ICD implantation and LV reconstruction were evaluated. During admission, two-dimensional (2D) echocardiography (LV volumes and LVEF) was performed before surgery and was repeated at 3 months after surgery. Over a median follow-up of 18 months, the incidence of ICD therapy was evaluated.
RESULTS:
The study population consisted of 37 patients (59 +/- 11 years). At baseline, mean LVEF was 23 +/- 5%. Mean left ventricular end-systolic volume (LVESV) and left ventricular end-diastolic volume (LVEDV) were 175 +/- 73 mL and 225 +/- 88 mL, respectively. At 3-month follow-up, mean LVEF was 41 +/- 9% (P < 0.0001 vs. baseline), and mean LVESV and LVEDV were 108 +/- 65 mL and 176 +/- 73 mL, respectively (P < 0.0001 vs. baseline). During 18-month follow-up, 12 (32%) patients had ventricular arrhythmias, resulting in appropriate ICD therapy. No significant relations existed between baseline LVEF (P = 0.77), LVEF at 3-month follow-up (P = 0.34), change in LVEF from baseline to 3-month follow-up (P = 0.28), and the occurrence of ICD therapy during 18-month follow-up.
CONCLUSION:
LVEF before and after surgical LV reconstruction is of limited use as criterium for ICD implantation in patients with end-stage heart failure.
AuthorsSjoerd A Mollema, Patrick Klein, Jogien Heersche, Martin J Schalij, Ernst E Van der Wall, Michel I M Versteegh, Robert J M Klautz, Lieselot Van Erven, Jeroen J Bax
JournalPacing and clinical electrophysiology : PACE (Pacing Clin Electrophysiol) Vol. 32 Issue 7 Pg. 913-7 (Jul 2009) ISSN: 1540-8159 [Electronic] United States
PMID19572868 (Publication Type: Clinical Trial, Journal Article, Research Support, Non-U.S. Gov't)
Topics
  • Defibrillators, Implantable
  • Female
  • Heart Failure (complications, diagnostic imaging, prevention & control)
  • Humans
  • Male
  • Middle Aged
  • Patient Selection
  • Plastic Surgery Procedures
  • Stroke Volume
  • Treatment Outcome
  • Ultrasonography
  • Ventricular Dysfunction, Left (diagnostic imaging, etiology, prevention & control)

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: