Abstract | OBJECTIVES: Acute and long-term results after sirolimus-eluting stent (SES) implantation of proximal left anterior descending coronary artery (LAD) disease were evaluated. BACKGROUND: Although SES has been used increasingly for the treatment of LAD disease, data regarding their safety and efficacy in a real-world population are limited. METHODS: We investigate the short- and long-term results in 966 patients who underwent SES implantation for stenosis of proximal LAD. RESULTS: The procedural success rate was 97.6%, and procedural non-Q-wave myocardial infarction (MI) rate was 14.5%. In-hospital major complications occurred in five patients (0.5%), including three deaths and two Q-wave MIs. During follow-up (20.4 +/- 8.9 months), there were 16 deaths (1.7%; 10 cardiac, 6 noncardiac), 2 Q-wave MIs, and 22 target lesion revascularizations (2.3%). Late stent thrombosis occurred in two patients (0.2%), 14 and 23 months after the procedure. The event-free survival rates for cardiac death/Q-wave MI were 98.6% +/- 0.4% at 1 year and 97.8% +/- 0.6% at 2 years. The cumulative probabilities of survival without major adverse cardiac events ( MACE) were 96.7% +/- 0.6% at 1 year and 95.4% +/- 0.8% at 2 years. In multivariate analysis, stented length (HR 1.04, 95%CI 1.01-1.07, P = 0.009) and infarct-related artery (HR 5.18, 95%CI 1.09-24.64, P = 0.039) were independently related to cardiac death/Q-wave MI. In addition, stented length (HR 1.04, 95%CI 1.02-1.06, P < 0.001) and left ventricular dysfunction (HR 2.66, 95%CI 1.07-6.63, P = 0.036) were significant independent predictors of MACE. CONCLUSIONS: SES implantation for proximal LAD disease appears safe and effective in a real-world population, and the independent predictors of MACE included stented length and left ventricular dysfunction.
|
Authors | Cheol Whan Lee, Chong-Hiok Tan, Jon Suh, Se-Whan Lee, Duk-Woo Park, Seung-Whan Lee, Young-Hak Kim, Myeong-Ki Hong, Jae-Joong Kim, Seong-Wook Park, Seung-Jung Park |
Journal | Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
(Catheter Cardiovasc Interv)
Vol. 70
Issue 3
Pg. 368-73
(Sep 2007)
ISSN: 1522-1946 [Print] United States |
PMID | 17722041
(Publication Type: Journal Article, Research Support, Non-U.S. Gov't)
|
Copyright | (c) 2007 Wiley-Liss, Inc. |
Chemical References |
- Coated Materials, Biocompatible
- Immunosuppressive Agents
- Sirolimus
|
Topics |
- Adult
- Aged
- Aged, 80 and over
- Blood Vessel Prosthesis Implantation
(instrumentation)
- Coated Materials, Biocompatible
- Coronary Angiography
- Coronary Disease
(diagnostic imaging, surgery)
- Electrocardiography
- Female
- Follow-Up Studies
- Humans
- Immunosuppressive Agents
(pharmacology)
- Male
- Middle Aged
- Myocardial Revascularization
(methods)
- Postoperative Complications
- Prognosis
- Retrospective Studies
- Sirolimus
(pharmacology)
- Stents
- Time Factors
|