MONITORING OF PULMONARY EDEMA USING ULTRASOUND RADIOFREQUENCY SIGNAL.

AbstractABSTRACT:
Objectives: Excessive accumulation of extravascular lung water impairs respiratory gas exchange and results in respiratory distress. Real-time radiofrequency signals of ultrasound can continuously and quantitatively monitor excessive lung water. This study aims to evaluate the availability of continuous real-time quantitative pulmonary edema monitoring using ultrasound radiofrequency signals and compare it with Pa o2 (partial pressure of arterial oxygen)/F io2 (fraction of inspired oxygen) (PF) ratio, conventional lung ultrasound, and the Hounsfield unit of chest computed tomography. Methods: Male Yorkshire pigs (40.5 ± 0.5 kg) were anesthetized and mechanically ventilated. A balanced crystalloid was administered to induce hydrostatic pulmonary edema. Three different infusion rates of 2, 4, and 6 mL/kg per minute were tested to determine the infusion rate for the appropriate swine model. The chest computed tomography and ultrasonography with radiofrequency signals were taken every 5 min during the full inspiration. The ultrasonography scans with radiofrequency signals were measured at the intercostal space where the line crossing the two armpits and the right anterior axillary line intersected. Results: The infusion rate of fluid for the pulmonary edema model was determined to be 6 mL/kg per minute, and a total of four pigs were tested at an injection rate of 6 mL/kg. The adjusted R2 values of regression analysis between the radiofrequency signal and computer tomography Hounsfield score were 0.990, 0.993, 0.988, and 0.993 (all P values <0.05). All radiofrequency signal changes preceded changes in PF ratio or lung ultrasound changes. The area under the receiver operating characteristic curve of the radiofrequency signal for predicting PF ratio <300 was 0.88 (95% confidence interval, 0.82-0.93). Conclusion: We evaluated ultrasound radiofrequency signals to assess pulmonary edema in a swine model that can worsen gradually and showed that quantitative ultrasound radiofrequency signal analysis could assess pulmonary edema and its progression before PF ratio or lung ultrasound changes.
AuthorsHyuksool Kwon, You Hwan Jo, Jae Hyuk Lee, Ji Eun Hwang, Inwon Park, Seonghye Kim, Dong-Hyun Jang, Doyun Kim, Hyunglan Chang
JournalShock (Augusta, Ga.) (Shock) Vol. 59 Issue 1 Pg. 118-124 (01 01 2023) ISSN: 1540-0514 [Electronic] United States
PMID36377364 (Publication Type: Journal Article, Research Support, Non-U.S. Gov't)
CopyrightCopyright © 2022 by the Shock Society.
Chemical References
  • Oxygen
Topics
  • Male
  • Animals
  • Swine
  • Pulmonary Edema (diagnostic imaging)
  • Lung (diagnostic imaging)
  • Extravascular Lung Water
  • Ultrasonography
  • Oxygen