Optimized Signal Quality Assessment for Photoplethysmogram Signals Using Feature Selection.

AbstractOBJECTIVE:
With the increasing use of wearable healthcare devices for remote patient monitoring, reliable signal quality assessment (SQA) is required to ensure the high accuracy of interpretation and diagnosis on the recorded data from patients. Photoplethysmographic (PPG) signals non-invasively measured by wearable devices are extensively used to provide information about the cardiovascular system and its associated diseases. In this study, we propose an approach to optimize the quality assessment of the PPG signals.
METHODS:
We used an ensemble-based feature selection scheme to enhance the prediction performance of the classification model to assess the quality of the PPG signals. Our approach for feature and subset size selection yielded the best-suited feature subset, which was optimized to differentiate between the clean and artifact corrupted PPG segments.
CONCLUSION:
A high discriminatory power was achieved between two classes on the test data by the proposed feature selection approach, which led to strong performance on all dependent and independent test datasets. We achieved accuracy, sensitivity, and specificity rates of higher than 0.93, 0.89, and 0.97, respectively, for dependent test datasets, independent of heartbeat type, i.e., atrial fibrillation (AF) or non-AF data including normal sinus rhythm (NSR), premature atrial contraction (PAC), and premature ventricular contraction (PVC). For independent test datasets, accuracy, sensitivity, and specificity rates were greater than 0.93, 0.89, and 0.97, respectively, on PPG data recorded from AF and non-AF subjects. These results were found to be more accurate than those of all of the contemporary methods cited in this work.
SIGNIFICANCE:
As the results illustrate, the advantage of our proposed scheme is its robustness against dynamic variations in the PPG signal during long-term 14-day recordings accompanied with different types of physical activities and a diverse range of fluctuations and waveforms caused by different individual hemodynamic characteristics, and various types of recording devices. This robustness instills confidence in the application of the algorithm to various kinds of wearable devices as a reliable PPG signal quality assessment approach.
AuthorsFahimeh Mohagheghian, Dong Han, Andrew Peitzsch, Nishat Nishita, Eric Ding, Emily L Dickson, Danielle DiMezza, Edith M Otabil, Kamran Noorishirazi, Jessica Scott, Darleen Lessard, Ziyue Wang, Cody Whitcomb, Khanh-Van Tran, Timothy P Fitzgibbons, David D McManus, Ki H Chon
JournalIEEE transactions on bio-medical engineering (IEEE Trans Biomed Eng) Vol. 69 Issue 9 Pg. 2982-2993 (09 2022) ISSN: 1558-2531 [Electronic] United States
PMID35275809 (Publication Type: Journal Article, Research Support, N.I.H., Extramural, Research Support, U.S. Gov't, Non-P.H.S.)
Topics
  • Algorithms
  • Artifacts
  • Atrial Fibrillation
  • Electrocardiography (methods)
  • Heart Rate
  • Humans
  • Photoplethysmography (methods)
  • Signal Processing, Computer-Assisted
  • Wearable Electronic Devices