Evaluation of Serum Cryptococcal Antigen Testing Using Two Novel Semiquantitative Lateral Flow Assays in Persons with Cryptococcal Antigenemia.

Abstract
Early cryptococcal disease can be detected via circulating antigen in blood before fulminant meningitis develops, when early antifungal therapy improves survival. Two semiquantitative cryptococcal antigen (CrAg) lateral flow assays (LFAs) have been developed, but their diagnostic performance has not been defined. Cryopreserved serum samples from HIV-infected Ugandans obtained as part of a prospective CrAg-screening cohort were tested in duplicate for CrAg by the CrAgSQ (IMMY) and CryptoPS (Biosynex) lateral flow assays. Case-controlled diagnostic performance was measured using the FDA-approved CrAg LFA (IMMY) as a reference standard via McNemar's test. Of 99 serum samples tested, 57 were CrAg positive (CrAg+) by the CrAg LFA reference standard. By CrAgSQ, 57 were read as positive, with 98% sensitivity (56/57; 95% confidence interval [CI], 0.91 to 0.99) and 98% specificity (41/42; 95% CI, 0.88 to 0.99) (McNemar's, P = 0.99). The sample with a false-negative result by CrAgSQ (n = 1) had a titer of <1:5, while the sample with a false-positive result (n = 1) yielded a 1+ result. By CryptoPS, 52 samples were read as positive, with 88% sensitivity (50/57; 95% CI, 0.76 to 0.95) and 95% specificity (40/42; 95% CI, 0.84 to 0.99) (McNemar's, P = 0.18). The CryptoPS false-negative results included samples with titers of <1:5 (n = 1), 1:5 (n = 5), and 1:20 (n = 1), while samples with false-positive results by CryptoPS (n = 2) yielded Positive results. The CryptoPS assay missed 35% (7/20) of samples with CrAg LFA titers of ≤1:20. The new semiquantitative CrAg LFAs allow rapid estimation of titer levels in easy-to-perform platforms. The CrAgSQ demonstrated better qualitative sensitivity and specificity than the CryptoPS compared to the reference standard. The exact grading of the CrAgSQ results has some subjectivity, with interreader variability; however, qualitative reads were generally concordant for both assays.
AuthorsCaleb Skipper, Kiiza Tadeo, Emily Martyn, Elizabeth Nalintya, Radha Rajasingham, David B Meya, Bosco Kafufu, Joshua Rhein, David R Boulware
JournalJournal of clinical microbiology (J Clin Microbiol) Vol. 58 Issue 4 (03 25 2020) ISSN: 1098-660X [Electronic] United States
PMID32024729 (Publication Type: Journal Article, Research Support, N.I.H., Extramural)
CopyrightCopyright © 2020 American Society for Microbiology.
Chemical References
  • Antigens, Fungal
Topics
  • Antigens, Fungal
  • CD4 Lymphocyte Count
  • Cryptococcus
  • HIV Infections (diagnosis)
  • Humans
  • Meningitis, Cryptococcal
  • Prospective Studies
  • Sensitivity and Specificity