Influence of tumor location on the intensity-modulated radiation therapy plan of helical tomotherapy.

Abstract
Given the design of the Helical TomoTherapy device, the patient's central axis is routinely aligned with the machine's rotational axis to prevent the patient's body from colliding with the machine walls. However, for treatment of tumors located away from the patient's central axis, this position may not be optimal as the adequate radiation dose may not reach the affected site. Our study aimed to investigate the influence of tumor location on dose quality and delivery efficiency of tomotherapy plans. A phantom and 15 patients were selected for this study. Two plans, A and B, were implemented for each case. In plan A, the patient's central axis was aligned with the machine's rotational axis, whereas in plan B, the center of the planning target volume (PTV) was aligned with the machine's rotational axis. Both plans were optimized with the same planning parameters, and the dose quality of the plans was evaluated using dosimetrics. The delivery efficiency was determined from delivery time and monitor units (MUs). A paired t-test or nonparametric Wilcoxon signed-rank test was performed for statistical comparison. In the phantom study, the median delivery times were 358 and 336 seconds for plans A and B, respectively, and this difference was significant (p = 0.005). In the patient study, the median delivery times were 348 and 317 seconds for plans A and B, respectively, and this difference was also significant (p = 0.001). The dose qualities of both plans for each patient were nearly identical. No significant differences were found in the conformal index, heterogeneity index, and mean dose delivered to normal tissue between the plans. Both phantom and patient studies showed that for normal-sized patients, the delivery time reduced as the distance between the PTV and the patient's central axis increased when the PTV center was aligned with the machine axis. In conclusion, aligning the PTV center with the machine's rotational axis by shifting the patient during tomotherapy reduces the delivery time without compromising the dose quality of intensity-modulated radiation therapy.
AuthorsYingjie Xu, Hui Yan, Zhihui Hu, Pan Ma, Kuo Men, Peng Huang, Wenting Ren, Jianrong Dai, Yexiong Li
JournalMedical dosimetry : official journal of the American Association of Medical Dosimetrists (Med Dosim) 2017 Winter Vol. 42 Issue 4 Pg. 334-340 ISSN: 1873-4022 [Electronic] United States
PMID28797719 (Publication Type: Journal Article)
CopyrightCopyright © 2017 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Topics
  • Humans
  • Neoplasms (radiotherapy)
  • Phantoms, Imaging
  • Radiotherapy Dosage
  • Radiotherapy Planning, Computer-Assisted (methods)
  • Radiotherapy, Intensity-Modulated (methods)