Safety and effectiveness of the Bonebridge transcutaneous active direct-drive bone-conduction hearing implant at 1-year device use.

Abstract
The objective of this study is to evaluate the safety and efficacy of a new transcutaneous bone-conduction implant (BCI BB) in patients with conductive and mixed hearing loss or with single-sided deafness (SSD), 1 year after surgical implantation. The study design is multicentric prospective, intra-subject measurements. Each subject is his/her own control. The setting is nine university hospitals: 7 French and 2 Belgian. Sixteen subjects with conductive or mixed hearing loss with bone-conduction hearing thresholds under the upper limit of 45 dB HL for each frequency from 500 to 4000 Hz, and 12 subjects with SSD (contralateral hearing within normal range) were enrolled in the study. All subjects were older than 18 years. The intervention is rehabilitative. The main outcome measure is the evaluation of skin safety, audiological measurements, benefit, and satisfaction questionnaires with a 1-year follow up. Skin safety was rated as good or very good. For the mixed or conductive hearing loss groups, the average functional gain (at 500 Hz, 1, 2, 4 kHz) was 26.1 dB HL (SD 13.7), and mean percentage of speech recognition in quiet at 65 dB was 95 % (vs 74 % unaided). In 5/6 SSD subjects, values of SRT in noise were lower with BB. Questionnaires revealed patient benefit and satisfaction. The transcutaneous BCI is very well tolerated at 1-year follow up, improves audiometric thresholds and intelligibility for speech in quiet and noise, and gives satisfaction to both patients with mixed and conductive hearing loss and patients with SSD.
AuthorsSébastien Schmerber, O Deguine, M Marx, P Van de Heyning, O Sterkers, I Mosnier, P Garin, B Godey, C Vincent, F Venail, M Mondain, A Deveze, J P Lavieille, A Karkas
JournalEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery (Eur Arch Otorhinolaryngol) Vol. 274 Issue 4 Pg. 1835-1851 (Apr 2017) ISSN: 1434-4726 [Electronic] Germany
PMID27475796 (Publication Type: Journal Article, Multicenter Study)
Topics
  • Adult
  • Audiometry
  • Bone Conduction
  • Female
  • Hearing Aids
  • Hearing Loss, Conductive (surgery)
  • Hearing Loss, Mixed Conductive-Sensorineural (surgery)
  • Humans
  • Male
  • Middle Aged
  • Patient Satisfaction
  • Prospective Studies
  • Prostheses and Implants
  • Speech Perception
  • Surveys and Questionnaires
  • Treatment Outcome

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: