HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Cardiovascular magnetic resonance imaging of myocardial oedema following acute myocardial infarction: Is whole heart coverage necessary?

AbstractBACKGROUND:
AAR measurement is useful when assessing the efficacy of reperfusion therapy and novel cardioprotective agents after myocardial infarction. Multi-slice (Typically 10-12) T2-STIR has been used widely for its measurement, typically with a short axis stack (SAX) covering the entire left ventricle, which can result in long acquisition times and multiple breath holds. This study sought to compare 3-slice T2-short-tau inversion recovery (T2- STIR) technique against conventional multi-slice T2-STIR technique for the assessment of area at risk (AAR).
METHODS:
CMR imaging was performed on 167 patients after successful primary percutaneous coronary intervention. 82 patients underwent a novel 3-slice SAX protocol and 85 patients underwent standard 10-slice SAX protocol. AAR was obtained by manual endocardial and epicardial contour mapping followed by a semi- automated selection of normal myocardium; the volume was expressed as mass (%) by two independent observers.
RESULTS:
85 patients underwent both 10-slice and 3-slice imaging assessment showing a significant and strong correlation (intraclass correlation coefficient = 0.92;p < 0.0001) and a low Bland-Altman limit (mean difference -0.03 ± 3.21%, 95% limit of agreement,- 6.3 to 6.3) between the 2 analysis techniques. A further 82 patients underwent 3-slice imaging alone, both the 3-slice and the 10-slice techniques showed statistically significant correlations with angiographic risk scores (3-slice to BARI r = 0.36, 3-slice to APPROACH r = 0.42, 10-slice to BARI r = 0.27, 10-slice to APPROACH r = 0.46). There was low inter-observer variability demonstrated in the 3-slice technique, which was comparable to the 10-slice method (z = 1.035, p = 0.15). Acquisition and analysis times were quicker in the 3-slice compared to the 10-slice method (3-slice median time: 100 seconds (IQR: 65-171 s) vs. (10-slice time: 355 seconds (IQR: 275-603 s); p < 0.0001.
CONCLUSIONS:
AAR measured using 3-slice T2-STIR technique correlates well with standard 10-slice techniques, with no significant bias demonstrated in assessing the AAR. The 3-slice technique requires less time to perform and analyse and is therefore advantageous for both patients and clinicians.
AuthorsStephen Hamshere, Daniel A Jones, Cyril Pellaton, Danielle Longchamp, Tom Burchell, Saidi Mohiddin, James C Moon, Jens Kastrup, Didier Locca, Steffen E Petersen, Mark Westwood, Anthony Mathur
JournalJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance (J Cardiovasc Magn Reson) Vol. 18 Pg. 7 (Jan 23 2016) ISSN: 1532-429X [Electronic] England
PMID26803468 (Publication Type: Comparative Study, Journal Article, Multicenter Study, Research Support, Non-U.S. Gov't)
Chemical References
  • Contrast Media
  • Organometallic Compounds
  • Meglumine
  • gadoterate meglumine
Topics
  • Aged
  • Clinical Trials as Topic
  • Contrast Media
  • Edema, Cardiac (etiology, pathology)
  • Europe
  • Female
  • Humans
  • Magnetic Resonance Imaging, Cine (methods)
  • Male
  • Meglumine
  • Middle Aged
  • Myocardial Infarction (complications, pathology, therapy)
  • Myocardium (pathology)
  • Observer Variation
  • Organometallic Compounds
  • Percutaneous Coronary Intervention
  • Predictive Value of Tests
  • Reproducibility of Results

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: