Abstract | BACKGROUND: The MGuard (MG) is a stainless-steel closed cell stent covered with an ultra-thin polymer mesh sleeve, which has the purpose of ensuring reduced distal embolization of thrombotic material, thus lowering the risk of no-reflow/slow-flow phenomena. Only few data are available that evaluated the usefulness of the MG stent in patients with ST-elevation myocardial infarction ( STEMI) with a high thrombotic burden. METHODS: We prospectively collected data of patients presenting with STEMI and high thrombotic burden ( thrombus burden grade 4 or 5 according to the TIMI score) who underwent primary percutaneous coronary intervention (PCI) with MG stent implantation in our center. Lesions involving a bifurcation or very calcified and tortuous vessels were not included. Final TIMI 3 flow, normal myocardial blush grade (MBG), and complete ST-segment resolution were defined as short-term endpoints, whereas major adverse cardiovascular events were evaluated during follow-up. RESULTS: From August 2008 to June 2013, the MG stent was implanted in 104 (9.3%) of 1108 patients who underwent primary PCI. Cardiogenic shock on admission was present in 4 patients (3.8%). Final TIMI 3 flow was achieved in 97.1% of patients, MBG 3 in 56.7%, and regression of ST-segment elevation ≥70% within 90 min was recorded in 64.4% of patients. In-hospital mortality was 2.9% (n=3), and at a mean follow-up of 455±430 days overall major adverse cardiovascular events were 11 (10.6%). Cardiac death occurred in 5 patients (4.9%) and stent thrombosis in 2 (1.9%). CONCLUSIONS: In selected patients with STEMI undergoing primary PCI, the use of the mesh-covered MG stent in vessels with high thrombotic burden despite thrombus aspiration was effective and safe both immediately and at mid-term follow-up.
|
Authors | Enrico Cerrato, Cristina Rolfo, Francesco Tomassini, Nicolò Montali, Alfonso Gambino, Vincenzo Infantino, Sara Palacio Restrepo, Denise Baricocchi, Rosa Nevola, Andrea Gagnor, Ferdinando Varbella |
Journal | Giornale italiano di cardiologia (2006)
(G Ital Cardiol (Rome))
Vol. 16
Issue 6
Pg. 373-9
(Jun 2015)
ISSN: 1827-6806 [Print] Italy |
Vernacular Title | MGuard "Dacron mesh covered" stent per il trattamento della sindrome coronarica acuta con sopraslivellamento del tratto ST in presenza di elevato carico trombotico: outcome intraospedaliero e a lungo termine in un singolo centro ad alto volume. |
PMID | 26156698
(Publication Type: Journal Article)
|
Chemical References |
- Anticoagulants
- Polyethylene Terephthalates
|
Topics |
- Aged
- Anticoagulants
(therapeutic use)
- Combined Modality Therapy
- Coronary Angiography
- Coronary Circulation
- Coronary Thrombosis
(complications, diagnostic imaging, drug therapy, surgery)
- Equipment Design
- Female
- Hospitals, Special
- Humans
- Male
- Middle Aged
- Myocardial Infarction
(etiology, physiopathology, surgery)
- Percutaneous Coronary Intervention
(adverse effects, instrumentation)
- Polyethylene Terephthalates
- Postoperative Complications
(etiology, prevention & control)
- Prospective Studies
- Severity of Illness Index
- Stents
(adverse effects)
- Surface Properties
- Thromboembolism
(etiology, prevention & control)
- Treatment Outcome
|