HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Impact of iodine delivery rate with varying flow rates on image quality in dual-energy CT of patients with suspected pulmonary embolism.

AbstractRATIONALE AND OBJECTIVES:
To prospectively compare four contrast material injection protocols for dual-energy computed tomography (CT) pulmonary angiography (DE-CTPA) in patients with suspected pulmonary embolism (PE).
MATERIALS AND METHODS:
One hundred twenty consecutive patients were randomized to contrast material injection protocols defined by different iodine concentrations and iodine delivery rates (IDRs): (A) 80 mL iopromide 370/4 mL/sec = IDR 1.4 gI/sec; (B) 80 mL iopromide 370 at 3 mL/sec = IDR 1.1 gI/sec; (C) 98 mL iopromide 300 at 4.9 mL/sec = IDR 1.4 gI/sec; and (D) 98 mL iopromide 300 at 3.7 mL/sec = IDR 1.1 gI/sec. Attenuation values were measured in the inflow tract (subclavian vein-superior vena cava-right atrium), target tract (right ventricle-pulmonary trunk-pulmonary arteries), and outflow tract (left atrium-left ventricle-ascending aorta). Two readers assessed subjective image quality of CTPA images and iodine perfusion maps. The number of artifacts due to hyperdense contrast material on iodine perfusion maps was recorded.
RESULTS:
Target tract attenuation was highest for protocol A with 374 ± 98 Hounsfield units (HU) (highly concentrated contrast material/high IDR). This was significant compared to protocols B and D (P = .0118, P = .0427) but not compared to protocol C (P = .3395). No significant difference in target tract attenuation was found between protocols B (309 ± 80 HU), protocol C (352 ± 119 HU), and D (325 ± 74 HU). CTPA and iodine perfusion map image quality for protocol A was rated significantly higher compared to all other protocols (median score = 5/4; P < .0001 for both) with moderate interreader agreement (κ = 0.58/0.47). Protocols A and B displayed increased artifacts on iodine perfusion maps compared to protocols C and D (3 versus 2).
CONCLUSION:
Despite increased artifacts on iodine perfusion maps, highly concentrated iodinated contrast material combined with high flow rates provides improved diagnostic image quality and has the highest target-tract attenuation for DE-CTPA protocols.
AuthorsJan Hansmann, Christian Fink, Gregor Jost, Hubertus Pietsch, Mathias Meyer, John W Nance Jr, Uwe J Schoepf, Ulrike I Attenberger, Stefan O Schoenberg, Thomas Henzler
JournalAcademic radiology (Acad Radiol) Vol. 20 Issue 8 Pg. 962-71 (Aug 2013) ISSN: 1878-4046 [Electronic] United States
PMID23746688 (Publication Type: Journal Article, Randomized Controlled Trial)
CopyrightCopyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.
Chemical References
  • Contrast Media
  • Iohexol
  • iopromide
Topics
  • Adult
  • Aged
  • Aged, 80 and over
  • Contrast Media (administration & dosage)
  • Female
  • Humans
  • Iohexol (administration & dosage, analogs & derivatives)
  • Male
  • Middle Aged
  • Pulmonary Embolism (diagnostic imaging)
  • Radiographic Image Enhancement (methods)
  • Radiography, Dual-Energy Scanned Projection (methods)
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed (methods)

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: