Monte Carlo simulation of contrast-enhanced whole brain radiotherapy on a CT scanner.

AbstractPURPOSE:
To perform a feasibility study of contrast-enhanced whole brain radiotherapy for treating patients with multiple brain metastasis using a conventional computed tomography (CT) scanner.
METHODS:
The treatment dose was optimized to be applied in a single run using a maximum tube power of 5200 kWs at 140 kV. CT scans of a large and a small head were used as reference. Irradiation geometry, shielding, axial beam collimation, radial beam collimation, gantry tilt, and tube current for beam modulation were optimized using a Monte Carlo simulation and a contrast agent concentration of 5 mg/ml iodine in the tumor. The statistical uncertainty of the Monte Carlo simulation was corrected using back convolution.
RESULTS:
Using a CT tube with a beam collimation of 28.8 mm, a mean tumor dose of 1.76 +/- 0.13 Gy was achieved, while the head bone dose was 2.61 +/- 0.18 Gy with a normal brain dose of 0.98 +/- 0.06 Gy, eye dose of 0.19 +/- 0.05 Gy, and lens dose of 0.15 +/- 0.03 Gy, respectively. Using a CT tube with dose modulation and a beam collimation of 40.0 mm, the mean tumor dose was 2.00 +/- 0.11 Gy with a head bone dose of 1.96 +/- 0.14 Gy, normal brain dose of 1.13 +/- 0.08 Gy, eye dose of 0.21 +/- 0.05 Gy, and lens dose of 0.16 +/- 0.02 Gy, respectively. Thus a standard CT scanner enables an effective tumor dose of 37.0 Gy to be administered in 13 fractions, while exposing healthy brain to an effective dose of 17.2 Gy and head bone to 69.3 Gy. Additional radial collimation implemented in the hardware improves the therapeutic tumor dose by 25.2% in relation to the bone dose.
CONCLUSIONS:
Contrast-enhanced total brain radiotherapy is feasible using a conventional CT tube with optimized dose application.
AuthorsBernd-Joachim Schultz, Peter Wust, Lutz Lüdemann, Gregor Jost, Hubertus Pietsch
JournalMedical physics (Med Phys) Vol. 38 Issue 8 Pg. 4672-80 (Aug 2011) ISSN: 0094-2405 [Print] United States
PMID21928641 (Publication Type: Evaluation Study, Journal Article)
Chemical References
  • Contrast Media
  • Iodine
Topics
  • Brain Neoplasms (diagnostic imaging, radiotherapy, secondary)
  • Computer Simulation
  • Contrast Media
  • Eye (radiation effects)
  • Humans
  • Iodine
  • Monte Carlo Method
  • Phantoms, Imaging
  • Radiation Protection
  • Skull (radiation effects)
  • Tomography, X-Ray Computed

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: