HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Lumen-apposing covered self-expandable metal stents for short benign gastrointestinal strictures: a multicenter study.

Abstract
Background and study aim Use of the fully covered self-expandable metal stent (SEMS) for benign luminal gastrointestinal (GI) stricture (BLGS) has been limited by the migration rate. The role of the lumen-apposing metal stent (LAMS) for BLGS is not well defined. We assessed the safety, feasibility, and efficacy of LAMS for the treatment of BLGS. Patients and methods This was an observational, open-label, retrospective, single-arm, multicenter consecutive case series of patients undergoing LAMS placement for BLGS. Technical success was defined as successful placement of the LAMS. Short- and long-term clinical success rates were defined as symptom improvement/resolution with indwelling stent and after stent removal, respectively. All adverse events and additional interventions were recorded. Results A total of 30 patients (mean age 51.6 years; 63.3 % women) underwent LAMS placement for GI strictures (83.9 % anastomotic). Median stricture diameter and length were 4.5 mm (range 2 - 10 mm) and 8 mm (range 5 - 10 mm), respectively. Technical success was achieved in 29 patients (96.7 %), with an adverse event rate of 13.3 %. The stent migration rate was 8.0 % (2/25) on follow-up endoscopy. Short-term clinical success was achieved in 90.0 % (27/30) at a median of 60 days (interquartile range [IQR] 40 - 90 days). Most patients (19/23; 82.6 %) experienced sustained symptom improvement/resolution without the need for additional interventions at a median follow-up of 100 days (IQR 60 - 139 days) after LAMS removal. Conclusion This multicenter study demonstrated that LAMS placement represents a safe, feasible, and effective therapeutic option for patients with BLGS and is associated with a low stent migration rate. Our initial findings suggest that future prospective comparative studies are needed on the use of LAMS, endoscopic dilation, and conventional SEMS. .
AuthorsDennis Yang, Jose M Nieto, Ali Siddiqui, Brian P Riff, Christopher J DiMaio, Satish Nagula, Amr M Ismail, Saowanee Ngamreungphong, Mouen A Khashab, Mihir S Wagh, Demetrios Tzimas, Jonathan M Buscaglia, Daniel S Strand, Andrew Y Wang, Shailendra S Chauhan, Christopher E Forsmark, Peter V Draganov
JournalEndoscopy (Endoscopy) Vol. 49 Issue 4 Pg. 327-333 (Apr 2017) ISSN: 1438-8812 [Electronic] Germany
PMID28114688 (Publication Type: Journal Article, Multicenter Study, Observational Study)
Copyright© Georg Thieme Verlag KG Stuttgart · New York.
Topics
  • Adult
  • Aged
  • Constriction, Pathologic (therapy)
  • Endoscopy, Gastrointestinal
  • Feasibility Studies
  • Female
  • Humans
  • Intestinal Diseases (therapy)
  • Male
  • Middle Aged
  • Prosthesis Design
  • Prosthesis Failure (etiology)
  • Retrospective Studies
  • Self Expandable Metallic Stents (adverse effects)
  • Treatment Outcome

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: