Abstract |
A simple, rapid, sensitive and reliable high performance liquid chromatography (HPLC) method for the determination of the anti- ulcer drug sofalcone in human plasma was developed. Plasma was extracted with ethyl acetate under acidic conditions and sofalcone was determined by HPLC using a C18 column and ( methanol-0.1% formic acid aqueous 80:20) mobile phase. The linear calibration curves of sofalcone in human plasma were obtained over the concentration range of 0.01-5.0 microg/ml. The lower limit of quantitation (LLOQ) was 10 ng/ml in human plasma. The precision measured for plasma was within 15%. Extraction recovery was over 85% in blood. The method was successfully applied to the identification and quantification of sofalcone in pharmacokinetic studies.
|
Authors | Aidong Wen, Zhipeng Wang, Taijun Hang, Yanyan Jia, Tingting Zhang, Yin Wu, Xuan Gao, Zhifu Yang |
Journal | Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
(J Chromatogr B Analyt Technol Biomed Life Sci)
Vol. 856
Issue 1-2
Pg. 348-52
(Sep 01 2007)
ISSN: 1570-0232 [Print] Netherlands |
PMID | 17586104
(Publication Type: Journal Article)
|
Chemical References |
- Anti-Ulcer Agents
- Chalcones
- sofalcone
|
Topics |
- Anti-Ulcer Agents
(blood, pharmacokinetics)
- Calibration
- Chalcones
(blood, pharmacokinetics)
- Chromatography, High Pressure Liquid
(methods)
- Humans
- Quality Control
- Sensitivity and Specificity
|