HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

A comparison of the insulin tolerance/glucagon test with the short ACTH stimulation test in the assessment of the hypothalamo-pituitary-adrenal axis in the early post-operative period after hypophysectomy.

AbstractOBJECTIVE:
The insulin tolerance test (ITT) is the established reference test for assessing the hypothalamo-pituitary-adrenal (HPA) axis. Various authorities, however, have suggested that the 250 microgram short ACTH stimulation test may be used to assess the HPA axis in place of the ITT in suspected hypopituitarism, although a number of other studies have suggested that the test may be unreliable in this setting. In this study, the ITT (or glucagon test) has been compared with the 250 microgram short ACTH stimulation test in patients with pituitary tumours pre-operatively and within 2 weeks of trans-sphenoidal hypophysectomy.
DESIGN:
An ITT, or a glucagon test when the ITT was contraindicated, and the 250 micrograms short ACTH stimulation test, were performed in all the patients before (an ITT in 18 and a glucagon test in three patients) and within 2 weeks after trans-sphenoidal hypophysectomy (an ITT in 16 and a glucagon test in five patients).
PATIENTS:
Twenty-one patients with pituitary disorders (15 with acromegaly, one with a prolactinoma and five with non-functioning tumours) were studied; four had a microadenoma, two a mesoadenoma and 15 a macroadenoma.
MEASUREMENTS:
Serum cortisol was measured by radioimmunoassay. A normal response was defined as a rise in serum cortisol to 580 nmol/l or above for all the tests.
RESULTS:
Before surgery, three of 18 patients (17%) had a discrepancy between the ITT and the 30 minute short ACTH stimulation test and one of three between the glucagon test and the 30 minute short ACTH stimulation test. Combined together, pre-operatively, four of 21 patients (19%) had discrepant results. In the early post-operative period, the discrepancy between ITT and the 30 minute short ACTH stimulation test was higher with four of 16 patients (25%) showing discordant results; one of the five patients tested had a discrepancy between the glucagon test and the 30 minute short ACTH stimulation test. On combining the tests, the post-operative discrepancy was five of 21 patients (24%).
CONCLUSIONS:
The 250 microgram short ACTH stimulation test produces discordant results from the ITT in a clinically significant proportion of affected patients when assessing the HPA axis, although the rate of discordance varies according to the criteria used for normality for both the tests. We suggest that the ITT should remain the preferred test for assessing ACTH secretory capacity compared with the standard 250 microgram short ACTH stimulation test, both in the preoperative and in the early post-trans-sphenoidal hypophysectomy period.
AuthorsJ J Mukherjee, J J de Castro, G Kaltsas, F Afshar, A B Grossman, J A Wass, G M Besser
JournalClinical endocrinology (Clin Endocrinol (Oxf)) Vol. 47 Issue 1 Pg. 51-60 (Jul 1997) ISSN: 0300-0664 [Print] England
PMID9302372 (Publication Type: Comparative Study, Journal Article)
Chemical References
  • Insulin
  • Adrenocorticotropic Hormone
  • Glucagon
Topics
  • Adenoma (physiopathology, surgery)
  • Adrenocorticotropic Hormone
  • Female
  • Glucagon
  • Humans
  • Hypophysectomy
  • Hypothalamo-Hypophyseal System (physiopathology)
  • Insulin
  • Male
  • Middle Aged
  • Pituitary Neoplasms (physiopathology, surgery)
  • Pituitary-Adrenal System (physiopathology)
  • Postoperative Period
  • Predictive Value of Tests

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: