HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Seroma prevention in a rat mastectomy model: use of a light-activated fibrin sealant.

Abstract
Seroma formation following mastectomy and axillary dissection remains a common and significant problem contributing to patient morbidity and health-care costs. Previous data have suggested that fibrin sealant (FS), a biological adhesive, is capable of controlling lymphatic leakage and assisting with skin graft adhesion. In this study, the use of an experimental, light-activated FS under development by CryoLife (CFS) was evaluated in a rat mastectomy model in order to reduce seroma formation. CFS is a premixed form of FS, containing an inactivator that is reversed in the presence of light, causing sealant to form. In this model, rats underwent mastectomy and extensive dissection of the axillary lymphovasculature. Next, 1 ml of saline or FS was applied to the operative site and the wound was closed. Three groups of animals were evaluated 5 days postoperatively by measuring the volume (in milliliters) of seroma able to be aspirated from the surgical site. The saline control group (N = 20) had a seroma volume (mean +/- standard deviation [SD]) of 4.2 +/- 2.9 ml, while a form of CFS containing human fibrinogen (80 to 100 mg per milliliter) and human thrombin (20 U per milliliter) (N = 20) had a significantly smaller seroma volume of 1.1 +/- 1.6 ml (p < 0.001 analysis of variance). University of Virginia (UVA) FS, containing human fibrinogen (20 mg per milliliter) and bovine thrombin (500 U per milliliter) (N = 20), had a seroma volume of 2.0 +/- 1.6 ml (p < 0.01, compared to control; p > 0.2, compared to CFS). Thus, this form of CFS significantly reduced seroma formation compared to saline control and also appeared to result in a smaller fluid accumulation than with UVA FS, although this trend was not statistically significant. These data suggest that the use of CFS may help to reduce seroma formation in humans.
AuthorsJ Y Wang, N C Goodman, L R Amiss Jr, D H Nguyen, G T Rodeheaver, M M Moore, R F Morgan, R D Abbott, W D Spotnitz
JournalAnnals of plastic surgery (Ann Plast Surg) Vol. 37 Issue 4 Pg. 400-5 (Oct 1996) ISSN: 0148-7043 [Print] United States
PMID8905048 (Publication Type: Clinical Trial, Comparative Study, Journal Article, Randomized Controlled Trial)
Chemical References
  • Fibrin Tissue Adhesive
Topics
  • Animals
  • Female
  • Fibrin Tissue Adhesive
  • Mastectomy (adverse effects)
  • Prospective Studies
  • Rats
  • Rats, Sprague-Dawley

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: