Abstract |
The effect of different mouth pieces on efficacy of fenoterol was studied in 40 patients with atopic and non-atopic bronchial asthma with reversible bronchial constriction. Four devices were studied: standard MDI unit, MDI unit with Boehringer and Astra mouth pieces, MDI unit with spacer. PEF values were registered 7 hours following inhalation. Statistical differences were not significant within the whole group. In selected older patients (above 60 years of age) spacer and Astra mouth pieces produced significant changes.
|
Authors | J Ciszek, A Kazimierczak, S Wesołowski |
Journal | Pneumonologia i alergologia polska
(Pneumonol Alergol Pol)
Vol. 61
Issue 3-4
Pg. 120-6
( 1993)
ISSN: 0867-7077 [Print] Poland |
Vernacular Title | Analiza skuteczności fenoterolu podawanego w aerozolu przy uzyciu róznych ustników. |
PMID | 8364424
(Publication Type: English Abstract, Journal Article)
|
Chemical References |
|
Topics |
- Adult
- Aerosols
- Asthma
(drug therapy)
- Equipment Design
- Female
- Fenoterol
(administration & dosage)
- Humans
- Male
- Middle Aged
- Nebulizers and Vaporizers
|