HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Termination of atrioventricular nodal reentrant tachycardia by premature stimulation from ablating catheter. A reliable guide to identify site for slow-pathway ablation.

AbstractBACKGROUND:
Slow-pathway ablation is currently used more frequently to control atrioventricular nodal reentrant tachycardia (AVNRT). However, in patients with the common type of AVNRT, successful ablation of the slow pathway can be difficult and time-consuming. We tested a simple method to predict a site for slow-pathway ablation in patients with AVNRT of the common variety.
METHODS AND RESULTS:
Twenty patients with symptomatic common AVNRT (13 women and 7 men; mean age, 41 +/- 21 years) were included in the study. Once the AVNRT had a stable cycle length (+/- 10 ms) for at least 20 cycles, single extrastimuli were delivered from the ablating catheter tip beginning with 20 ms less than the tachycardia cycle length and decrementing by 10 ms until tachycardia terminated or loss of capture occurred at the pacing site. The pacing protcol was performed systematically in a stepwise fashion at four adjacent sites starting from the posterior/inferior interatrial septum near the tricuspid annulus and moving progressively more anteriorly. The pacing protocol was then repeated in the same sequence, followed by delivery of radiofrequency current at each site to determine its effect at sites where AVNRT could not be terminated with a pacing protocol. AVNRT could be terminated in the anterograde direction from at least one site in 19 patients. Tachycardia could be terminated at two or more adjacent sites in 5 patients. The longest atrial coupling interval at the site of tachycardia termination was 67 +/- 27 ms (range, 30 to 130 ms) less than the AVNRT cycle length. Resetting of subsequent His bundle depolarization (H2), producing an H-H2 interval prolongation of 26 +/- 24 ms (range, 10 to 80 ms), occurred in 17 patients before termination of the tachycardia. In 18 of the 19 patients, the slow pathway was successfully ablated at the site at which AVNRT was terminated at the longest atrial coupling interval.
CONCLUSIONS:
Termination of tachycardia in the anterograde direction at the longest atrial coupling interval by extrastimuli delivered from the ablating catheter can be helpful for identification of an optimal site for slow-pathway ablation in patients with the common variety of AVNRT.
AuthorsJ Sra, M Jazayeri, A Natale, A Dhala, Z Blanck, S Deshpande, C Maglio, S Bremner, M Akhtar
JournalCirculation (Circulation) Vol. 91 Issue 4 Pg. 1095-100 (Feb 15 1995) ISSN: 0009-7322 [Print] United States
PMID7850946 (Publication Type: Journal Article)
Topics
  • Adult
  • Atrioventricular Node (physiopathology, surgery)
  • Cardiac Pacing, Artificial (methods)
  • Catheter Ablation (methods)
  • Electrophysiology
  • Female
  • Heart Conduction System (physiopathology)
  • Humans
  • Male
  • Tachycardia, Atrioventricular Nodal Reentry (diagnosis, physiopathology, surgery)

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: