Argon laser treatment of a pupillary membrane in pseudophakia.

Abstract
A method of opening an opacified, retrolental, intrapupillary membrane in a pseudophakic eye, using the argon laser, is presented. The procedure was safe, and the membrane remained retracted one year after treatment.
AuthorsM H Seelenfreund, I Sternberg, I Hirsch
JournalJournal - American Intra-Ocular Implant Society (J Am Intraocul Implant Soc) Vol. 8 Issue 2 Pg. 166-7 ( 1982) ISSN: 0146-2776 [Print] United States