There are several limitations in using absolute myocardial clearance of
thallium-201 for the detection of
coronary artery disease. Noncardiac factors such as peak exercise heart rate and blood level of
thallium can affect its absolute myocardial clearance. However, because all myocardial segments in a given heart are exposed to the same noncardiac factors, a relative difference in myocardial clearance of
thallium between segments could reflect the presence of
coronary artery disease. Accordingly, myocardial clearance of
thallium was analyzed in 370 patients. Patients in Group I (n = 45) had less than 1% probability of having
coronary artery disease, patients in Group II (n = 44) had normal coronary arteries and patients in Group III (n = 281) had
coronary artery disease. Although mean myocardial clearance of
thallium in 15 myocardial segments in three views in Group I subjects was 3.4 +/- 0.7 hours, the variability between the slowest and fastest clearing segments in the same subject was as much as 98%. This variability was systematic, suggesting technical reasons associated with imaging as the cause of the variability: 78% of the slowest clearing segments were basal whereas 53% of the fastest clearing segments were apical (p less than 0.01). When Group II and III patients were compared based on Group I values, the absolute myocardial clearance of
thallium had a sensitivity and specificity of 92 and 16%, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)