HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Externally stented polytetrafluoroethylene valved conduits for right heart reconstruction. An experimental comparison with Dacron valved conduits.

Abstract
Valve-containing conduits have made possible the repair of many congenital anomalies that involve right ventricular-pulmonary arterial discontinuity. The distressing problem of neointimal peel formation with eventual conduit obstruction in patients with Dacron valved conduits has led to the need for premature replacement in many patients. Externally stented polytetrafluorethylene has demonstrated superior patency in the venous system experimentally and clinically and was believed to have potential advantages over Dacron for conduit construction. This study compares the transconduit resistance and the thickness of the neointimal peel in right ventricular-pulmonary arterial conduits constructed of externally stented polytetrafluoroethylene with those of woven Dacron. The 19 mm externally stented polytetrafluoroethylene conduits (Impra, Inc.) containing a Hancock porcine valve (Extracorporeal Inc.) were implanted in six adult mongrel dogs followed by proximal occlusion of the pulmonary artery. In six additional animals, a Dacron valved conduit of similar size and length was inserted. Cardiac output, transconduit gradient, and resistance were measured at operation and at 3 months. All conduits were subsequently explanted, opened longitudinally, and the thickness of the neointimal peel (excluding suture lines) measured. No hemodynamic differences were noted during the 3 month follow-up. However, the thickness of the neointimal peel was fourfold greater in Dacron conduits (609 +/- 144 mu) than in the conduits constructed of externally stented polytetrafluoroethylene (156 +/- 50 mu) (p less than 0.01). The thick peel in Dacron conduits extended into the outflow portion of the porcine valve cusps and prevented their full excision. The neointima in externally stented polytetrafluoroethylene conduits was thin and uniform and did not extend onto the leaflets or limit their mobility. This study demonstrated that the early hemodynamic performance of externally stented polytetrafluoroethylene conduits was comparable to that of Dacron conduits; Dacron conduits were subject to an accelerated rate of peel formation that affected leaflet mobility and may be a factor in early valve degeneration; a thin neointima formed in externally stented polytetrafluoroethylene conduits and valve leaflet motion was preserved. This study showed that externally stented polytetrafluoroethylene conduits offer advantages over Dacron valved conduits and warrant clinical application.
AuthorsJ W Brown, M P Halpin, F J Rescorla, B W VanNatta, A C Fiore, G D Shipley, M Bizuneh, R Bills, B Waller
JournalThe Journal of thoracic and cardiovascular surgery (J Thorac Cardiovasc Surg) Vol. 90 Issue 6 Pg. 833-41 (Dec 1985) ISSN: 0022-5223 [Print] United States
PMID2933562 (Publication Type: Comparative Study, Journal Article)
Chemical References
  • Polyethylene Terephthalates
  • Polytetrafluoroethylene
Topics
  • Animals
  • Bioprosthesis
  • Blood Vessel Prosthesis
  • Dogs
  • Heart Valve Prosthesis
  • Heart Ventricles (surgery)
  • Polyethylene Terephthalates
  • Polytetrafluoroethylene
  • Pulmonary Artery (surgery)

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: