AbstractBACKGROUND:
Hemodialysis (HD) access failure is a common cause of increased morbidity and healthcare cost in patients with end stage renal disease (ESRD). Percutaneous balloon angioplasty has been used to treat hemodialysis access stenosis but is complicated by a high rate of restenosis. Percutaneous cutting balloon (PCB) angioplasty is an alternative approach that has shown to reduce restenosis.
OBJECTIVES:
The aim of the study is to assess the safety and efficacy of PCB angioplasty in comparison with conventional and high-pressure balloon angioplasty in the treatment of hemodialysis access site stenosis.
METHODS:
We searched PubMed, EMBASE and the Cochrane Central register of controlled trials (CENTRAL) databases through August 2014 and selected studies using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) checklist. We included all randomized clinical trials with a head-to-head comparison between PCB and conventional or high-pressure balloon angioplasty
RESULTS:
Three studies with 1034 participants (age 60.7 (±12.9) years and 50.1% males) with 525 in PCB and 509 in control arm were included in the analysis. The immediate procedural success rate was not significantly different in the PCB angioplasty and control arm respectively, (87.2% vs. 83.7% RD -0.02; 95%CI -0.06 to 0.01; P = 0.38). The six-month target lesion patency was significantly higher in the PCB angioplasty arm (67.2% vs. 55.6% RD 0.12; 95%CI 0.05-0.19; P < 0.05) with number needed to treat (NNT) of 9. The device related complications were not statistically significant between groups (RD 0.03; 95%CI -0.02 to 0.07; P = 0.26).
CONCLUSIONS:
PCB angioplasty is effective in treatment of hemodialysis access stenosis, with significantly higher six-month patency compared to balloon angioplasty.
AuthorsShiv Kumar Agarwal, Girish N Nadkarni, Rabi Yacoub, Achint A Patel, James S Jenkins, Tyrone J Collins, Narender Annapureddy, Damodar Kumbala, Shirisha Bodana, Alexandre M Benjo
JournalJournal of interventional cardiology (J Interv Cardiol) Vol. 28 Issue 3 Pg. 288-95 (Jun 2015) ISSN: 1540-8183 [Electronic] United States
PMID25989717 (Publication Type: Comparative Study, Journal Article, Meta-Analysis, Review, Systematic Review)
Copyright© 2015, Wiley Periodicals, Inc.
Topics
  • Angioplasty, Balloon (methods)
  • Arteriovenous Shunt, Surgical
  • Constriction, Pathologic (therapy)
  • Humans
  • Randomized Controlled Trials as Topic
  • Renal Dialysis
  • Vascular Patency

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: