Simulation study comparing high-purity germanium and cadmium zinc telluride detectors for breast imaging.

Abstract
We conducted simulations to compare the potential imaging performance for breast cancer detection with High-Purity Germanium (HPGe) and Cadmium Zinc Telluride (CZT) systems with 1% and 3.8% energy resolution at 140 keV, respectively. Using the Monte Carlo N-Particle (MCNP5) simulation package, we modelled both 5 mm-thick CZT and 10 mm-thick HPGe detectors with the same parallel-hole collimator for the imaging of a breast/torso phantom. Simulated energy spectra were generated, and planar images were created for various energy windows around the 140 keV photopeak. Relative sensitivity and scatter and the torso fractions were calculated along with tumour contrast and signal-to-noise ratios (SNR). Simulations showed that utilizing a ±1.25% energy window with an HPGe system better suppressed torso background and small-angle scattered photons than a comparable CZT system using a -5%/+10% energy window. Both systems provided statistically similar contrast and SNR, with HPGe providing higher relative sensitivity. Lowering the counts of HPGe images to match CZT count density still yielded equivalent contrast between HPGe and CZT. Thus, an HPGe system may provide equivalent breast imaging capability at lower injected radioactivity levels when acquiring for equal imaging time.
AuthorsD L Campbell, T E Peterson
JournalPhysics in medicine and biology (Phys Med Biol) Vol. 59 Issue 22 Pg. 7059-79 (Nov 21 2014) ISSN: 1361-6560 [Electronic] England
PMID25360792 (Publication Type: Journal Article, Research Support, N.I.H., Extramural, Research Support, Non-U.S. Gov't, Research Support, U.S. Gov't, Non-P.H.S.)
Chemical References
  • CdZnTe
  • Germanium
  • Cadmium
  • Zinc
  • Tellurium
Topics
  • Breast (diagnostic imaging)
  • Cadmium (chemistry)
  • Computer Simulation
  • Female
  • Germanium (chemistry)
  • Humans
  • Image Processing, Computer-Assisted (methods)
  • Monte Carlo Method
  • Phantoms, Imaging
  • Photons
  • Positron-Emission Tomography (instrumentation, methods)
  • Radionuclide Imaging (instrumentation)
  • Signal-To-Noise Ratio
  • Tellurium (chemistry)
  • Zinc (chemistry)

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: