HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Ablation of typical atrial flutter: a prospective study of cooled-tip versus 8-mm-tip catheters.

AbstractAIM:
Both ablation catheters with irrigated system and 8mm tip-catheters have shown to be more effective for typical atrial flutter radiofrequency (RF) ablation when compared to conventional 4 mm tip catheter. The purpose of this prospective study was to compare the efficiency of radiofrequency catheter ablation (RFA) of the cavotricuspid isthmus using a new type of open irrigation-tip catheter versus 8 mm tip-catheters to eliminate atrial flutter (AFL).
METHODS:
Sixty consecutive patients, matched for age, presence of cardiopathy, atrial dimensions and comorbidity, underwent RF ablation of cavotricuspid isthmus (CTI) for the treatment of typical atrial flutter, using an open irrigated tip catheter - Surround Flow™ - (N.=30) or an 8-mm-tip catheter (N.=30). The RF pulses were applied point-by-point for 30 seconds, with power limited at 35 w for the irrigated catheter and by temperature control (60/70 w) for the 8-mm catheter.
RESULTS:
The CTI block was successfully performed in 100% of cases. There was no significant difference with regard to ablation parameters, such as total time of RF ablation (608±324 vs. 556±244 s, P=0.79), number of RF applications (12±8 vs. 10±5, P=0.56), total procedure duration (86.4±23.6 vs. 78.1±22.5 min, P=0.58) and time of fluoroscopy (12±6 vs. 14±6 min, P=0.25) and periprocedural complications (1 groin hematoma in the 8 mm group). During follow-up of 11.6 months on average, one patient in the 8 mm group had recurrence of typical atrial flutter.
CONCLUSION:
Efficacy and safety of CTI ablation was comparable between both techniques (open irrigated catheter and 8mm tip catheter). The ablation parameters were comparable and homogeneous between the two groups.
AuthorsM Iori, N Bottoni, F Quartieri, B Sassone, S Guerzoni
JournalMinerva cardioangiologica (Minerva Cardioangiol) Vol. 62 Issue 3 Pg. 283-6 (Jun 2014) ISSN: 1827-1618 [Electronic] Italy
PMID24831764 (Publication Type: Comparative Study, Controlled Clinical Trial, Journal Article, Multicenter Study)
Topics
  • Aged
  • Atrial Flutter (surgery)
  • Catheter Ablation (adverse effects, instrumentation, methods)
  • Catheters
  • Equipment Design
  • Female
  • Follow-Up Studies
  • Humans
  • Male
  • Middle Aged
  • Prospective Studies
  • Recurrence
  • Time Factors
  • Treatment Outcome

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: