HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Metaxalone estimation in biological matrix using high-throughput LC-MS/MS bioanalytical method.

Abstract
Metaxalone is a skeletal muscle relaxant, an approved drug for pain relief. Published bioanalytical methods lacked detailed stability evaluation in blood and plasma. An accurate, precise, high-throughput tandem mass spectroscopic method has been developed and validated. Following solid phase extraction (SPE), metaxalone and the internal standard metaxalone-d(3) were extracted from an aliquot of 200 μL of human plasma. Chromatographic separation achieved on an Ascentis Express C18 column (50 mm × 4.6 mm i.d., 2.7 μm particle size) with mobile phase is a mixture of 10mM ammonium acetate buffer (pH 4.5)-methanol-acetonitrile (20:50:30, v/v/v), at an isocratic flow rate of 0.7 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI) source. The mass transitions of metaxalone and metaxalone-d(3) were m/z 222.3→161.2 and m/z 225.3→163.3, respectively. The linear calibration curves were obtained in the concentration range of 0.105-10.081 μg/mL (r(2)≥0.99) with a lower limit of quantification (LLOQ) of 0.105 μg/mL. The intra- and inter-day precisions and relative error were all within 6%. Despite achieving high mean recovery (>78%), no interference peaks or matrix effects were observed. Detailed stability exercises including drug stability in blood, hemolyzed, lipemic and normal plasma were conducted to extend the method applicability in vast majority of clinical studies using 800 mg metaxalone extended release oral dosage form.
AuthorsDipanjan Goswami, Arabinda Saha, Sanjay Gurule, Arshad Khuroo, Tausif Monif, Poonam Vats
JournalJournal of chromatography. B, Analytical technologies in the biomedical and life sciences (J Chromatogr B Analyt Technol Biomed Life Sci) Vol. 902 Pg. 132-6 (Aug 01 2012) ISSN: 1873-376X [Electronic] Netherlands
PMID22766230 (Publication Type: Journal Article, Research Support, Non-U.S. Gov't)
CopyrightCopyright © 2012 Elsevier B.V. All rights reserved.
Chemical References
  • Oxazolidinones
  • metaxalone
Topics
  • Adult
  • Chromatography, Liquid (methods)
  • Drug Stability
  • Hemolysis
  • High-Throughput Screening Assays (methods)
  • Humans
  • Hyperlipidemias (blood)
  • Linear Models
  • Male
  • Oxazolidinones (blood, chemistry)
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Solid Phase Extraction
  • Tandem Mass Spectrometry (methods)

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: