HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

[Fibrin glue embolization treating intra-operative type I endoleak of endovascular repair of abdominal aortic aneurysm: long-term result].

AbstractOBJECTIVES:
To analyze the long-term results of fibrin glue embolization to eliminate type I endoleaks after endovascular aneurysm repair (EVAR), and to assess the feasibility and durability of this technique.
METHODS:
From August 2002 to June 2010, among the 953 EVAR patients, 51 (5.4%) patients underwent intraoperative transcatheter fibrin glue sac embolization to resolve type I endoleak persisting after initial intraoperative maneuvers to close the leak or in necks too short or angulated for cuff placement. Computed tomographic angiography was performed to assess the outcome after 3, 6, and 12 months and annually thereafter. A retrospective study was conducted, and characteristics of the patients, intra-sac pressure, hospital course, and long-term outcomes were recorded.
RESULTS:
Among the 51 patients, 19 (37.3%) patients had proximal necks long < 10 mm, and 6 (11.8%) patients had proximal neck angulation > 60°; 22 patients (3 additional iliac extension, 14 cuffs, and/or 8 stents) had been placed with additional devices. After fibrin glue injection, 50 (98.0%) of the 51 endoleaks were successfully resolved, and intra-sac pressure (including systolic, diastolic, mean pressures, pulse pressure, and the mean pressure indexes) decreased significantly in these cases. The patient who failed embolotherapy was converted to open surgery (2.0%); he died 2 months later from multiorgan failure. And other two (4.8%) patients died in the peri-operative period from myocardial infarction. The median of follow-up of 48 patients was 45 months (range 4 - 106 months). The mean maximal aneurysm diameter fell from the baseline (61.5 ± 15.2) mm to (48.8 ± 10.1) mm (P = 0.000). Three (6.2%) patients died in the follow-up duration (1 aneurysm-related, died of renal failure which was caused by the compromised renal artery). Cumulative survival was 97.9% at 1 year, 94.5% at 3 years, and 90.8% at 4 years. No recurrent type I endoleak or glue-related complications were observed in follow-up.
CONCLUSIONS:
Fibrin glue embolization to eliminate type I endoleak after EVAR has yielded promising results in this study, and it can effectively and durable resolve the type I endoleaks. Balloon occlusion of the inflow of the endoleak must be done during glue injection, to enhance the safety and facilitate formation of a structured fibrin clot.
AuthorsJia-Xuan Feng, Qing-sheng Lu, Zai-Ping Jing, Yang Yang, Bing Nie, Jun-min Bao, Zhi-qing Zhao, Xiang Feng, Yi Hong, Yi-fei Pei, Liang-xi Yuan
JournalZhonghua wai ke za zhi [Chinese journal of surgery] (Zhonghua Wai Ke Za Zhi) Vol. 49 Issue 10 Pg. 883-7 (Oct 01 2011) ISSN: 0529-5815 [Print] China
PMID22321676 (Publication Type: English Abstract, Journal Article, Research Support, U.S. Gov't, Non-P.H.S.)
Chemical References
  • Fibrin Tissue Adhesive
Topics
  • Aged
  • Aged, 80 and over
  • Aortic Aneurysm, Abdominal (surgery, therapy)
  • Blood Vessel Prosthesis Implantation (adverse effects)
  • Embolization, Therapeutic (methods)
  • Endoleak (etiology, therapy)
  • Female
  • Fibrin Tissue Adhesive (therapeutic use)
  • Humans
  • Male
  • Middle Aged
  • Postoperative Complications (therapy)
  • Treatment Outcome

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: