Early biomechanical keratoconus pattern measured with an ocular response analyzer: curve analysis.

AbstractPURPOSE:
To estimate the ability of the Ocular Response Analyzer parameters to aid in the diagnosis of keratoconus in pre-laser in situ keratomileusis (LASIK) patients.
SETTING:
Department of Ophthalmology, Bordeaux 2 University, Bordeaux Cedex, France.
DESIGN:
Evaluation of diagnostic test.
METHODS:
This study compared eyes with mild stages of keratoconus (study group) with preoperative eyes that later had LASIK (control group). Corneas with a central thickness within 500 to 600 μm were targeted. The biomechanical measurements were acquired, and 12 parameters were analyzed after extraction from the signal data.
RESULTS:
The study group comprised 103 eyes and the control group, 97 eyes. The mean corneal hysteresis (CH) was 9.2 mm Hg in study eyes and 10.1 mm Hg in control eyes and the mean corneal resistance factor (CRF), 8.9 mm Hg and 10.6 mm Hg, respectively. For a threshold of 9.6, CH had a sensitivity of 66% with a specificity of 67%. For a threshold of 9.7, the CRF had a sensitivity of 72% and a specificity of 77%. For 6 biomechanical parameters, the probability that a patient would present with keratoconus was 3 in 1000 if 1 parameter was over the chosen threshold.
CONCLUSIONS:
If 1 of 6 parameters were over a chosen threshold, the probability that a patient would present with keratoconus would be almost 3 in 1000 instead of 9 in 1000 in a LASIK surgery cohort. Despite low sensitivity and specificity, some parameters provided by the corneal analyzer offered high negative likelihood ratios and deserve more study with bigger samples.
AuthorsDavid Touboul, Antoine Bénard, Ashraf M Mahmoud, Anne Gallois, Joseph Colin, Cynthia J Roberts
JournalJournal of cataract and refractive surgery (J Cataract Refract Surg) Vol. 37 Issue 12 Pg. 2144-50 (Dec 2011) ISSN: 1873-4502 [Electronic] United States
PMID21978610 (Publication Type: Evaluation Study, Journal Article)
CopyrightCopyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Topics
  • Adolescent
  • Adult
  • Biomechanical Phenomena (physiology)
  • Case-Control Studies
  • Child
  • Cornea (physiopathology)
  • Diagnostic Techniques, Ophthalmological
  • Elasticity (physiology)
  • False Negative Reactions
  • Female
  • Humans
  • Keratoconus (diagnosis, physiopathology, surgery)
  • Keratomileusis, Laser In Situ
  • Male
  • Middle Aged
  • Predictive Value of Tests
  • Preoperative Care
  • Probability
  • ROC Curve
  • Reproducibility of Results
  • Sensitivity and Specificity

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: