Pneumococcal meningitis post-cochlear implantation: potential routes of infection and pathophysiology.

AbstractOBJECTIVE:
This review describes the current concept of pneumococcal meningitis in cochlear implant recipients based on recent laboratory studies. It examines possible routes of Streptococcus pneumoniae infection to the meninges in cochlear implant recipients. It also provides insights into fundamental questions concerning the pathophysiology of pneumococcal meningitis in implant recipients.
DATA SOURCES:
Medline/PubMed database; English articles after 1960. Search terms: cochlear implants, meningitis, pneumococcus, streptococcus pneumonia.
REVIEW METHODS:
Narrative review. All articles relating to post-implant meningitis without any restriction in study designs were assessed and information extracted.
RESULTS:
The incidence of pneumococcal meningitis in cochlear implant recipients is greater than that of an age-matched cohort in the general population. Based on the current clinical literature, it is difficult to determine whether cochlear implantation per se increases the risk of meningitis in subjects with no existing risk factors for acquiring the disease. As this question cannot be answered in humans, the study of implant-related infection must involve the use of laboratory animals in order for the research findings to be applicable to a clinical situation. The laboratory research demonstrated the routes of infection and the effects of the cochlear implant in lowering the threshold for pneumococcal meningitis.
CONCLUSION:
The laboratory data complement the existing clinical data on the risk of pneumococcal meningitis post-cochlear implantation.
AuthorsBenjamin P C Wei, Robert K Shepherd, Roy M Robins-Browne, Graeme M Clark, Stephen J O'Leary
JournalOtolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery (Otolaryngol Head Neck Surg) Vol. 143 Issue 5 Suppl 3 Pg. S15-23 (Nov 2010) ISSN: 1097-6817 [Electronic] England
PMID20970686 (Publication Type: Journal Article, Research Support, Non-U.S. Gov't, Review)
CopyrightCopyright © 2010 American Academy of Otolaryngology–Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.
Topics
  • Animals
  • Biofilms
  • Cochlear Implantation (adverse effects)
  • Cochlear Implants (adverse effects)
  • Ear, Inner (injuries, pathology)
  • Humans
  • Meningitis, Pneumococcal (epidemiology, etiology, microbiology, physiopathology)
  • Prosthesis-Related Infections (epidemiology, etiology, microbiology, physiopathology)
  • Risk Factors
  • Streptococcus pneumoniae