HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Gadolinium-enhanced three-dimensional magnetization-prepared rapid gradient-echo (3D MP-RAGE) imaging is superior to spin-echo imaging in delineating brain metastases.

AbstractBACKGROUND:
Precisely defining the number and location of brain metastases is very important for establishing a treatment strategy for malignancies. Although magnetic resonance imaging (MRI) is now considered the best modality, various improvements in sequences are still being made.
PURPOSE:
To prospectively compare the diagnostic ability of three-dimensional, magnetization-prepared rapid gradient-echo (3D MP-RAGE) imaging in detecting metastatic brain tumors, with that of two-dimensional spin-echo (2D SE) T1-weighted imaging.
MATERIAL AND METHODS:
A total of 123 examinations were included in this study, and 119 examinations from 88 patients with known malignancies were analyzed. All patients underwent T1- and T2-weighted 2D SE transverse imaging, followed by gadolinium-enhanced T1-weighted transverse and coronal 2D SE imaging and 3D MP-RAGE transverse imaging. Four radiologists interpreted the images to compare the accuracy and the time required for interpretation for each imaging.
RESULTS:
3D MP-RAGE imaging was significantly better than 2D SE imaging for detecting metastatic brain lesions, regardless of the readers' experience. The sensitivities of the 3D MP-RAGE and 2D SE imaging for all observers were 0.81 vs. 0.80 (P>0.05), specificities were 0.93 vs. 0.87 (P<0.05), positive predictive values were 0.92 vs. 0.86 (P<0.05), negative predictive values were 0.78 vs. 0.75 (P>0.05), and accuracies were 0.84 vs. 0.78 (P<0.05), respectively. There was no significant difference in the time required for image interpretation between the two modalities (15.6+/-4.0 vs. 15.4+/-4.1 min).
CONCLUSION:
3D MP-RAGE imaging proved superior to 2D SE imaging in the detection of brain metastases.
AuthorsT Takeda, A Takeda, T Nagaoka, E Kunieda, K Takemasa, M Watanabe, T Hatou, S Oguro, M Katayama
JournalActa radiologica (Stockholm, Sweden : 1987) (Acta Radiol) Vol. 49 Issue 10 Pg. 1167-73 (Dec 2008) ISSN: 1600-0455 [Electronic] England
PMID18979271 (Publication Type: Clinical Trial, Journal Article)
Chemical References
  • Contrast Media
  • Gadolinium DTPA
Topics
  • Adult
  • Aged
  • Aged, 80 and over
  • Brain Neoplasms (diagnosis, secondary)
  • Contrast Media
  • Female
  • Gadolinium DTPA
  • Humans
  • Image Enhancement (methods)
  • Imaging, Three-Dimensional (methods)
  • Magnetic Resonance Imaging (methods)
  • Magnetics
  • Male
  • Middle Aged
  • Observer Variation
  • Predictive Value of Tests
  • Prospective Studies
  • Reproducibility of Results
  • Sensitivity and Specificity

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: