HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Tracheal ceramic rings for tracheomalacia: a review after 17 years.

AbstractBACKGROUND:
Despite different support techniques, the surgical management of tracheomalacia is still a challenging problem. Satisfactory results after internal stenting are above 80%, whereas, when performing external stenting using biocompatible ceramic rings, results are reported at over 90%.
OBJECTIVE:
The purpose of this study was to examine the efficiency of surgical treatment in patients with segmentary tracheomalacia using external ceramic ring grafts.
METHODS:
In this retrospective study, we collected data from 12 patients who underwent surgery during the last 17 years for symptomatic segmentary tracheomalacia by use of biocompatible aluminum-oxide ceramic rings. All except one patient had undergone previous tracheostomy, six had a history of long-term intubation, two had previous trauma, and two patients had previous cancer treatment including radiotherapy. One of the patients still had an existing tracheostoma, which was closed when a ceramic ring was implanted. Tracheal wall collapse with pseudoglottis formation or flattened anterior-posterior tracheal diameter was documented with fiberoscopy at rest, and both pre- and postoperative airway resistance measurements were performed in all 12 patients using a spirometer. After malacic segments were found to be expandable using rigid tracheoscopy while the patient was under general anesthesia, preparation of the trachea was performed using a midline vertical incision in the neck. Subsequently, the malacic trachea was expanded by placing and suturing proper-sized ceramic ring(s) around it.
RESULTS:
In all patients, surgical expansion of the malacic segment using ceramic rings was successfully carried out without major complications while inspiratory stridor was resolved. Airway resistance decreased significantly from an average of 0.62 to 0.385 kPascal.
CONCLUSION:
Although the results of applying internal tracheal stents are encouraging, complications such as stent migration, granulation tissue and fistula formation, and mucociliary transport arrest are possible. Biocompatible ceramic rings do not cause foreign body reactions, remain stabile, and, with a proper suturing technique, provide a suitable long-term solution.
AuthorsGyula Göbel, Niki Karaiskaki, Imre Gerlinger, Wolf J Mann
JournalThe Laryngoscope (Laryngoscope) Vol. 117 Issue 10 Pg. 1741-4 (Oct 2007) ISSN: 0023-852X [Print] United States
PMID17690604 (Publication Type: Journal Article)
Chemical References
  • Biocompatible Materials
Topics
  • Adolescent
  • Adult
  • Aged
  • Biocompatible Materials
  • Ceramics (therapeutic use)
  • Female
  • Humans
  • Male
  • Middle Aged
  • Retrospective Studies
  • Spirometry
  • Stents
  • Tracheal Diseases (physiopathology, surgery, therapy)
  • Tracheotomy

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: