AbstractPURPOSE:
To investigate the refractive and visual outcomes of hyperopic LASIK using Esiris/Schwind technology.
METHODS:
This retrospective non-comparative observational study included 106 eyes (65 patients) operated with the Esiris/Schwind laser for hyperopia. Eyes were divided into two groups: group 1, < or = +3.99 diopters (D) and group 2, > or = +4.0 D (up to +7.0 D). Visual outcome for distance and near uncorrected (UCVA) and best spectacle-corrected visual acuities (BSCVA) (decimal values), cycloplegic refraction, keratometry (K), pachymetry, and complications were evaluated.
RESULTS:
In group 1, mean UCVA was 0.4 +/- 0.1 preoperatively and 0.8 +/- 0.2 6 months postoperatively. Mean BSCVA was 0.9 +/- 0.1 preoperatively and 0.9 +/- 0.1 6 months postoperatively. Safety index was 1.1 and efficacy index was 0.97. Mean spherical equivalent refraction was +2.33 +/- 0.9 D preoperatively and +0.3 +/- 0.3 D 6 months postoperatively. Mean K reading was 43.7 +/- 1.1 D preoperatively and 45.0 +/- 1.6 D 6 months postoperatively. In group 2, mean UCVA was 0.3 +/- 0.1 preoperatively and 0.8 +/- 0.2 6 months postoperatively. Mean BSCVA was 0.9 +/- 0.1 preoperatively and 0.9 +/- 0.1 6 months postoperatively. Safety index was 0.98 and efficacy index was 0.92. Mean spherical equivalent refraction was +5.1 +/- 0.9 D preoperatively and +0.4 +/- 0.5 D 6 months postoperatively. Mean K reading was 43.1 +/- 1.6 D preoperatively and 46.0 +/- 1.4 D 6 months postoperatively. Forty-six (90.2%) of 51 eyes in group 1 and 47 (85.5%) of 55 eyes in group 2 were within +/- 0.5 D of emmetropia. At 6-month follow-up, 40 (78%) of 51 eyes in group 1 had UCVA of 20/20 compared to 41 (75%) of 51 eyes in group 2. One (2%) of 51 eyes in group 1 and 4 (7.3%) of 55 eyes in group 2 lost < or = 2 lines of BSCVA. No eye lost >2 lines of BSCVA.
CONCLUSIONS:
Hyperopic LASIK with Esiris/Schwind technology is effective and safe in the correction of hyperopia up to + 7.0 D. Although a slight statistical significance was found for low hyperopia, visual and refractive results obtained in high hyperopia were encouraging.
AuthorsJorge Alió, Ahmed Galal, Maria José Ayala, Alberto Artola
JournalJournal of refractive surgery (Thorofare, N.J. : 1995) (J Refract Surg) Vol. 22 Issue 8 Pg. 772-81 (Oct 2006) ISSN: 1081-597X [Print] United States
PMID17061714 (Publication Type: Journal Article, Research Support, Non-U.S. Gov't)
Topics
  • Adult
  • Female
  • Follow-Up Studies
  • Humans
  • Hyperopia (physiopathology, surgery)
  • Keratomileusis, Laser In Situ (methods)
  • Male
  • Middle Aged
  • Refraction, Ocular
  • Retrospective Studies
  • Treatment Outcome
  • Visual Acuity

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: