Residual
oil fly ash (ROFA) is a particulate
pollutant comprised of soluble and insoluble metals and is produced by the combustion of
fossil fuels. The objective was to examine the pulmonary responses to chemically distinct ROFA samples collected from either a precipitator or air heater within the same power plant. The collected ROFA samples were suspended in saline (total sample), incubated for 24 h at 37 degrees C, centrifuged, separated into soluble and insoluble fractions, and the
metal composition was determined. In addition, electron spin resonance (ESR) was used to detect short-lived
free radical intermediates produced by the ROFA samples and the different fractions. On day 0, Male Sprague-Dawley rats were intratracheally instilled with saline (vehicle control) or the ROFA samples (1 mg/100 g body wt). At day 1, bronchoalveolar lavage was performed, and
lung inflammation was assessed. On day 3, additional rats that had been treated with ROFA were intratracheally inoculated with 5 x 10(5) Listeria monocytogenes, and pulmonary bacterial clearance was measured at days 6, 8, and 10. The precipitator ROFA was found to be more soluble and acidic with a significantly greater mass of each
metal compared with the air heater ROFA. A prominent
hydroxyl radical signal was measured for the total and soluble precipitator ROFA after the addition of H2O2, whereas the air heater ROFA and its fractions did not produce a signal. Precipitator ROFA induced a greater inflammatory response than air heater ROFA illustrated by a significant elevation in lung neutrophils. In addition, pulmonary clearance of L. monocytogenes was greatly diminished in the rats treated with the soluble and total precipitator ROFA samples. None of the air heater ROFA samples had an effect on lung bacterial clearance. In conclusion, precipitator ROFA, particularly the soluble fraction, generated a
metal-dependent
hydroxyl radical as measured by ESR and was shown to cause more
inflammation and result in reduced lung defense against
infection compared with air heater ROFA. These results are most likely due to differences in
metal composition and solubility of the ROFA samples.