HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Superparamagnetic iron oxide (SPIO) enhancement in the cirrhotic liver: a comparison of two doses of ferumoxides in patients with advanced disease.

Abstract
The aim of this study was to establish whether enhancement of the liver by the MRI contrast agent ferumoxides could be effectively achieved at a reduced dose of 7.5 micromol/kg in patients with advanced liver cirrhosis. Forty-two liver transplant candidates with end-stage cirrhosis underwent SPIO-enhanced MRI at 1.5T, using either 15 micromol/kg or 7.5 micromol/kg ferumoxides. The lower dose of ferumoxides was also used in 21 non-cirrhotic patients with colorectal liver metastases who acted as a control group. The percentage signal intensity loss (PSIL) after SPIO was measured in all patients, and in those patients with tumors the post-SPIO contrast-to-noise ratio (CNR) was measured. The median PSIL after SPIO in the high dose cirrhotic (HDLC), low dose non-cirrhotic (LDNC) and low dose cirrhotic (LDLC) patients was 86.3%, 74.6%, and 64.2% respectively. These differences were significant using the Mann-Whitney U test. Tumors were found in 8 patients in the high dose cirrhotic group, 9 in the low dose cirrhotic group, and all 21 of the control group. No significant differences were found between the CNR values after SPIO in the 3 groups (median values HDLC 15.1, LDNC 23.7, LDLC 19.5). In patients with late-stage cirrhosis the PSIL after SPIO was significantly less at 7.5 micromol/kg than at 15 micromol/kg, but both doses produced a substantial loss of signal. Lesion to liver CNR was not adversely affected by using the lower dose, so when imaging at 1.5T the authors would recommend using 7.5 micromol/kg in patients with liver cirrhosis.
AuthorsPaul Arnold, Janice Ward, Daniel Wilson, J Ashley Guthrie, Philip J Robinson
JournalMagnetic resonance imaging (Magn Reson Imaging) Vol. 21 Issue 7 Pg. 695-700 (Sep 2003) ISSN: 0730-725X [Print] Netherlands
PMID14559332 (Publication Type: Journal Article)
Chemical References
  • Contrast Media
  • Dextrans
  • Magnetite Nanoparticles
  • Oxides
  • Suspensions
  • Iron
  • ferumoxides
  • Ferrosoferric Oxide
Topics
  • Adult
  • Aged
  • Case-Control Studies
  • Contrast Media (administration & dosage)
  • Dextrans
  • Female
  • Ferrosoferric Oxide
  • Humans
  • Iron (administration & dosage)
  • Liver (pathology)
  • Liver Cirrhosis (pathology)
  • Liver Neoplasms (pathology, secondary)
  • Liver Transplantation
  • Magnetic Resonance Imaging
  • Magnetite Nanoparticles
  • Male
  • Middle Aged
  • Oxides (administration & dosage)
  • Suspensions

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: