HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Laser in situ keratomileusis for low myopia and astigmatism with a scanning spot excimer laser.

AbstractPURPOSE:
To determine the efficacy, predictability, safety, and short term stability of laser in situ keratomileusis (LASIK) in treating patients with low myopia and astigmatism using the Chiron Technolas Keracor 117 PlanoScan excimer laser.
METHODS:
We retrospectively studied the results of our initial 83 eyes with myopia ranging from -1.13 to -7.25 diopters (D) and astigmatism of no more than 4.00 D that underwent LASIK with the Chiron Technolas Keracor 117 PlanoScan. Follow-up was at 1 day, 1 month, and 3 to 6 months.
RESULTS:
Mean baseline spherical equivalent refraction was -3.54 +/- 1.41 D and cylinder -1.64 +/- 1.14 D. Mean postoperative spherical equivalent refraction was -0.52 +/- 0.50 D at 1 month and -0.65 +/- 0.62 D at 3 to 6 months; mean postoperative refractive cylinder was -0.45 +/- 0.54 D at 1 month and -0.50 +/- 0.63 D at 3 to 6 months. Fifty-three percent (44 eyes) achieved a spherical equivalent refraction within +/- 0.50 D and 81% (67 eyes) within +/- 1.00 D of emmetropia at the last examination. Fifty-seven percent (47 eyes) achieved a refractive cylinder of < or = 0.50 D, and 27% (22 eyes) had an undercorrection of their refractive cylinder at the last examination. An uncorrected visual acuity of 20/40 or better was achieved in 86% (71 eyes) of patients on postoperative day one, in 81% (67 eyes) at 1 month, and in 76% (63 eyes) at 3 to 6 months. Twenty-eight percent (23 eyes) saw 20/20 or better uncorrected at the last visit (41% [34 eyes] had a baseline spectacle-corrected visual acuity of 20/20). There was no statistically significant difference in the refractions or uncorrected visual acuities between the different postoperative examinations. No eye experienced a loss of spectacle-corrected visual acuity of more than one line at the last examination.
CONCLUSION:
LASIK with the Chiron PlanoScan excimer laser appears to be an effective, safe, and reasonably predictable means to reduce low myopia and astigmatism. Adjustment of computer algorithms is needed to decrease the number of under-corrections.
AuthorsR Zaldivar, J M Davidorf, M C Shultz, S Oscherow
JournalJournal of refractive surgery (Thorofare, N.J. : 1995) (J Refract Surg) 1997 Nov-Dec Vol. 13 Issue 7 Pg. 614-9 ISSN: 1081-597X [Print] United States
PMID9427198 (Publication Type: Journal Article)
Topics
  • Adult
  • Aged
  • Astigmatism (physiopathology, surgery)
  • Cornea (surgery)
  • Corneal Transplantation (methods)
  • Female
  • Follow-Up Studies
  • Humans
  • Laser Therapy
  • Male
  • Middle Aged
  • Myopia (physiopathology, surgery)
  • Predictive Value of Tests
  • Refraction, Ocular (physiology)
  • Retrospective Studies
  • Safety
  • Treatment Outcome
  • Visual Acuity (physiology)

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: