HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Cardiac Amyloidosis Imaging, Part 2: Quantification and Technical Considerations.

Abstract
99mTc-pyrophosphate imaging has been around for a long time. In the 1970s, it was used to image recent myocardial infarction. However, it has recently been recognized for its value in detecting cardiac amyloidosis, leading to widespread use across the United States. Increased use led to considerable procedure variability. As the evidence base to support formal guidelines was being developed, experts from several professional medical societies issued imaging and interpretation recommendations titled "ASNC/AHA/ASE/EANM/HFSA/ISA/SCMR/SNMMI Expert Consensus Recommendations for Multimodality Imaging in Cardiac Amyloidosis: part 1 of 2-Evidence Base and Standardized Methods of Imaging." To reach a consensus on a protocol that would benefit the bulk of laboratories, the experts considered several parameters and radiotracer kinetics. The most critical parameters concerned injection-to-imaging delay and planar imaging versus SPECT. Accordingly, the standardized protocol recommends the injection of 370-740 MBq (10-20 mCi) of 99mTc-pyrophosphate with imaging 3 h later. Planar images of the chest are acquired in the anterior and lateral views accompanied by SPECT images. Both the planar and the SPECT images are used to semiquantitatively grade the degree of myocardial uptake compared with the amount of uptake in the ribs using a 0-3 scale. A grade of 2 or 3 on the SPECT images is considered positive for cardiac amyloidosis. The planar images are used to calculate a heart-to-contralateral-lung ratio. A ratio greater than 1.3 at 3 h helps to confirm the diagnosis of cardiac amyloid if the SPECT images have positive findings. This article is part of a 3-part series in this issue of the Journal of Nuclear Medicine Technology Part 1 details the etiology of cardiac amyloidosis and 99mTc-pyrophosphate imaging acquisition parameters. Part 2, this article, describes the procedure evolution over 50 y, image processing, and quantification. It further discusses radiotracer kinetics and 2 important technical considerations: injection-to-imaging delay and planar imaging versus SPECT. Part 3 covers study interpretation along with cardiac amyloidosis diagnosis and treatment.
AuthorsEric J Schockling, Mary Beth Farrell, Monica Embry-Dierson, Jaime Warren, Scott Jerome
JournalJournal of nuclear medicine technology (J Nucl Med Technol) Vol. 51 Issue 2 Pg. 90-98 (Jun 2023) ISSN: 1535-5675 [Electronic] United States
PMID37268318 (Publication Type: Journal Article)
Copyright© 2023 by the Society of Nuclear Medicine and Molecular Imaging.
Chemical References
  • diphosphoric acid
  • Diphosphates
Topics
  • Humans
  • United States
  • Diphosphates
  • Cardiomyopathies
  • Amyloidosis (diagnostic imaging, therapy)
  • Heart

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: