Surgical fixation of isolated greater tuberosity fractures of the humerus- systematic review and meta-analysis.

AbstractOBJECTIVES:
A systematic review was undertaken based on PRISMA guidelines to study the results of surgical treatment of Greater Tuberosity fractures of the Humerus by different techniques (Open, Percutaneous or Arthroscopic) and using different fixation devices (Sutures, Screws and Plates).
DATA SOURCES:
Literature searches were performed for studies in English on four online databases (MEDLINE®, Embase®, Ovid® Emcare and CINAHL®) using a pre-planned search strategy.
STUDY SELECTION:
Studies were screened against pre-decided inclusion and exclusion criteria. 24 articles were eligible for inclusion involving 562 patients in all.
DATA EXTRACTION:
A template was used for collection of relevant data regarding the study design, demographics, fracture characteristics, surgical techniques and implants used, outcomes, complications and re-operations. Methodological quality was assessed using a modified Coleman Methodology Score.
DATA SYNTHESIS:
Pooled analysis was conducted for (1) complications/reoperations of different devices; and (2) reported results using standard outcome measures of various techniques. Results were pooled using inverse variance method. When pooling proportions, we used arcsine transformation to account for zero events.
CONCLUSION:
Use of screws was associated with higher rates of total complications (23.7%) as well as reoperations (13.2%), compared to sutures (14.2%; 2.6%) and plates (10.6%; 4.1%). In a subgroup analysis, use of low-profile plates (LPPs) was associated with the lowest rates of total complications (4.97%). The superiority of any surgical technique could not be established using the pooled Constant or ASES scores because there was lack of uniformity in the reporting of outcome measures. Our analysis of complications of the various fixation devices dissuades the use of screws and favours the use of low-profile plates. There is a need for prospective studies comparing arthroscopic suture fixation with open low-profile plate fixation of GT fractures.
AuthorsSachin Kumar, Arya Mishra, Hemant Singh, David Clark, Marius Espag, Amol Tambe
JournalJournal of clinical orthopaedics and trauma (J Clin Orthop Trauma) Vol. 23 Pg. 101670 (Dec 2021) ISSN: 0976-5662 [Print] India
PMID34790560 (Publication Type: Journal Article, Review)
Copyright© 2021 Delhi Orthopedic Association. All rights reserved.

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: