Personalized setting of plan parameters using feasibility dose volume histogram for auto-planning in Pinnacle system.

AbstractPURPOSE:
The personalized setting of plan parameters in the Auto-Planning module of the Pinnacle treatment planning system (TPS) using the PlanIQ feasibility tool was evaluated for lung cancer conventional fractionated radiotherapy (CFRT).
MATERIALS AND METHOD:
We reviewed the records of ten patients with lung cancer who were treated with volumetric modulated arc therapy (VMAT). Three plans were designed for each patient: the clinically accepted manual plan (MP) and two automatic plans including one generated using the generic plan parameters in technique script (AP1) and the other generated using personalized plan parameters derived based on feasibility dose volume histogram (FDVH) in PlanIQ (AP2). The plans were assessed according to the dosimetric parameters, monitor units, and planning time. A plan quality metric (PQM) was defined according to the clinical requirements for plan assessment.
RESULTS:
AP2 achieved better lung sparing than AP1 and MP. The PQM value of AP2 (52.5 ± 14.3) was higher than those of AP1 (49.2 ± 16.2) and MP (44.8 ± 16.9) with P < 0.05. The monitor units of AP2 (585.9 ± 142.9 MU) was higher than that of AP1 (511.1 ± 136.5 MU) and lower than that of MP (632.8 ± 143.8 MU) with p < 0.05. The planning time of AP2 (33.2 ± 4.8 min) was slightly higher than that of AP1 (28.2 ± 4.0 min) and substantially lower than that of MP (72.9 ± 28.5 min) with P < 0.05.
CONCLUSIONS:
The Auto-Planning module of the Pinnacle system using personalized plan parameters suggested by the PlanIQ Feasibility tool provides superior quality for lung cancer plans, especially in terms of lung sparing. The time consumption of Auto-Planning was slightly higher with the personalized parameters compared to that with the generic parameters, but significantly lower than that for the manual plan.
AuthorsWenlong Xia, Fei Han, Jiayun Chen, Junjie Miao, Jianrong Dai
JournalJournal of applied clinical medical physics (J Appl Clin Med Phys) Vol. 21 Issue 7 Pg. 119-127 (Jul 2020) ISSN: 1526-9914 [Electronic] United States
PMID32363757 (Publication Type: Journal Article)
Copyright© 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Topics
  • Feasibility Studies
  • Humans
  • Organs at Risk
  • Radiotherapy Dosage
  • Radiotherapy Planning, Computer-Assisted
  • Radiotherapy, Intensity-Modulated

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: