HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Five-year study of mandibular overdentures on stud abutments: Clinical outcome, patient satisfaction and prosthetic maintenance-Influence of bone resorption and implant position.

AbstractOBJECTIVES:
This prospective study analyses the 5-year clinical outcome, patient satisfaction and the technical outcome of a 2-implant overdenture on stud abutments. In addition, the influence of mandibular resorption and implant position on these outcomes was assessed.
MATERIAL AND METHODS:
Patients received two implants in a one-stage delayed protocol. Final prosthesis on stud abutments was finalized after 3 months. Implant survival, bone loss, plaque and sulcus bleeding index, OHIP-14, technical outcome and costs were assessed after 5 years. The Cawood-Howell classification defined the mandibular resorption. Inter-implant distances and angles (frontal, sagittal) were digitally measured. The significance level was p < .05.
RESULTS:
Fifty-six patients, 23 female and 33 males (mean age = 66.3, range 41-82), completed the follow-up. No implants were lost. Radiographical crestal bone loss was on average 1.25 mm (standard deviation SD 1.06), bleeding index was 0.75 (SD 0.73), and plaque index was 1.15 (SD 0.75) and higher for low mandibles (p = .001). The OHIP-14 reduction post-connection and after 5 years was significant (p < .001). Five-year maintenance required on average 6.7 (SD 4.8, range 0-25) interventions per patient. A larger inter-implant distance was associated with fewer replacement of retention inserts (p = .034) and less interventions (p = .006). Larger frontal (p = .023) and sagittal (p = .046) inter-implant angles (non-parallelism) required more inserts. The maintenance cost negatively influences the patient satisfaction (p = .004). 83% of the stud abutments showed wear.
CONCLUSION:
The implant overdenture on cylindrical stud abutments is a good and stable solution, irrespective of the resorption profile of the mandible. OHIP-14 improved permanently up to 5 years but is negatively influenced by complication cost. A small inter-implant distance, more frontal, sagittal inter-implant divergence increased maintenance.
AuthorsCarine Matthys, Stijn Vervaeke, Jos Besseler, Hugo De Bruyn
JournalClinical oral implants research (Clin Oral Implants Res) Vol. 30 Issue 9 Pg. 940-951 (Sep 2019) ISSN: 1600-0501 [Electronic] Denmark
PMID31264259 (Publication Type: Journal Article)
Copyright© 2019 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Chemical References
  • Dental Implants
Topics
  • Aged
  • Bone Resorption
  • Dental Implants
  • Dental Prosthesis, Implant-Supported
  • Denture Retention
  • Denture, Complete, Lower
  • Denture, Overlay
  • Female
  • Follow-Up Studies
  • Humans
  • Jaw, Edentulous
  • Male
  • Mandible
  • Patient Satisfaction
  • Prospective Studies
  • Treatment Outcome

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: