Comparison of everolimus-eluting bioresorbable vascular scaffolds and metallic stents: three-year clinical outcomes from the ABSORB China randomised trial.

AbstractAIMS:
Absorb bioresorbable vascular scaffolds (BVS) and XIENCE cobalt-chromium everolimus-eluting stents (CoCr-EES) had comparable angiographic and clinical outcomes up to one year in patients enrolled in the ABSORB China randomised trial. Whether these favourable results with BVS continue beyond one year up to three years is unknown. In this study we sought to analyse the outcomes from the trial up to three-year follow-up.
METHODS AND RESULTS:
ABSORB China was a prospective, open-label, multicentre trial in which 480 patients with one or two native coronary artery lesions were randomised 1:1 to BVS (N=241) vs. CoCr-EES (N=239). Clinical endpoints included target lesion failure (TLF; cardiac death, target vessel-related myocardial infarction or ischaemia-driven target lesion revascularisation), its components, and definite/probable stent/scaffold thrombosis (ST). There were no significant differences in clinical outcomes in patients treated with BVS and CoCr-EES up to three years, including TLF (5.5% vs. 4.7%, p=0.68) and definite/probable ST (0.9% vs. 0.0%, p=0.50). STs in the BVS arm consisted of one probable subacute event at 15 days and one definite very late event at 622 days. Among 32 BVS patients with a reference vessel diameter between 2.25 and 3.75 mm by quantitative coronary angiography and in whom post-dilatation was performed at >16 atm with a balloon:scaffold diameter >1:1 and balloon ≤scaffold diameter 0.5 mm, no TLF or ST events occurred within three years.
CONCLUSIONS:
In the ABSORB China trial, BVS and CoCr-EES had similar results up to three-year follow-up, the time at which the scaffold has completely resorbed. BVS outcomes may be further optimised by appropriate lesion selection and implantation technique.
AuthorsBo Xu, Yuejin Yang, Yaling Han, Yong Huo, Lefeng Wang, Xiangqian Qi, Jifu Li, Yundai Chen, Hai-Chien Kuo, Shih-Wa Ying, Wai-Fung Cheong, Yunlong Zhang, Xiaolu Su, Jeffrey J Popma, Runlin Gao, Gregg W Stone
JournalEuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology (EuroIntervention) Vol. 14 Issue 5 Pg. e554-e561 (Aug 03 2018) ISSN: 1969-6213 [Electronic] France
PMID30082268 (Publication Type: Journal Article, Randomized Controlled Trial)
Chemical References
  • Everolimus
Topics
  • Absorbable Implants
  • China
  • Drug-Eluting Stents
  • Everolimus
  • Humans
  • Percutaneous Coronary Intervention
  • Prospective Studies
  • Stents
  • Tissue Scaffolds
  • Treatment Outcome

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: