Abstract | OBJECTIVE: To assess the influence of adhesive core buildup designs (4-mm buildup, 2-mm buildup, and no buildup/endocrown) on the fatigue resistance and failure mode of endodontically treated molar teeth restored with lithium disilicate computer-aided design/computer-aided manufacturing (CAD/CAM) complete crowns placed with self- adhesive cement. METHODS AND MATERIALS: Forty-five extracted molars were decoronated at the level of the cementoenamel junction and endodontically treated. Specimens received different Filtek Z100 adhesive core buildups (4-mm buildup; 2-mm buildup; and no buildup endocrown preparation) and were restored with Cerec 3 CAD/CAM lithium disilicate crowns (IPS e.max CAD). The intaglio surfaces of restorations (n=15) were conditioned by hydrofluoric acid etching and silane, and prepared teeth were treated with airborne-particle abrasion, followed by cementation with RelyX Unicem 2 Automix. Specimens were then subjected to cyclic isometric loading at 10 Hz, beginning with a load of 200 N (×5000 cycles), followed by stages of 400, 600, 800, 1000, 1200, and 1400 N at a maximum of 30,000 cycles each. Specimens were loaded until failure or to a maximum of 185,000 cycles. The chewing cycle was simulated by an isometric contraction (load control) applied through a 10-mm in diameter composite resin sphere (Filtek Z100). Surviving specimens were axially loaded until failure or to a maximum load of 4500 N (crosshead speed 0.5 mm/min). The failure mode was assessed, and fractures were designated as catastrophic (tooth/root fracture that would require tooth extraction) or reparable (cohesive or cohesive/adhesive fracture of restoration only). Groups were compared using the life table survival analysis (log-rank test at p=0.05). Surviving specimens were loaded to failure and compared with one-way analysis of variance. RESULTS: The survival rates after the fatigue test were 100%, 93%, and 100% for 4-mm, 2-mm, and no buildup (endocrown), respectively and were not statistically different (only one specimen failed with a 2-mm buildup under a crown that cohesively fractured at 1,400 N). Postfatigue load to failure averaged 3181 N for 4-mm buildups (15 specimens), 3759 N for 2-mm buildups (12 specimens), and 3265 N for endocrowns (14 specimens). The 2-mm buildups were associated with higher loads to failure than endocrowns and 4-mm buildups, but no differences were found between 4-mm buildups and endocrowns (p<0.05.) One endocrown and 2 restorations with a 2-mm buildup survived the load-to-failure test (at 4500 N). Only catastrophic fractures occurred after the load-to-failure test. CONCLUSIONS: The buildup design influenced the performance of endodontically treated molars restored with lithium disilicate CAD/CAM complete crowns placed with self-adhesive resin cement. The 2-mm buildups were associated with higher loads to failure than the endocrown and the 4-mm buildup, but all restoration designs survived far beyond the normal range of masticatory forces.
|
Authors | A O Carvalho, G Bruzi, R E Anderson, H P Maia, M Giannini, P Magne |
Journal | Operative dentistry
(Oper Dent)
2016 Jan-Feb
Vol. 41
Issue 1
Pg. 76-82
ISSN: 1559-2863 [Electronic] United States |
PMID | 26266647
(Publication Type: Journal Article, Research Support, Non-U.S. Gov't)
|
Chemical References |
- Dental Cements
- Resin Cements
- lithia disilicate
- Dental Porcelain
|
Topics |
- Computer-Aided Design
- Crowns
- Dental Cements
- Dental Porcelain
- Dental Prosthesis Design
- Dental Restoration Failure
- Dental Stress Analysis
- Materials Testing
- Molar
- Resin Cements
|