HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Clinical and cone beam computed tomography comparison of NovaBone Dental Putty and PerioGlas in the treatment of mandibular Class II furcations.

AbstractOBJECTIVE:
The objective of this study is to compare the putty form of bioactive glass (NovaBone Dental Putty) and particulate form (PerioGlas) in the resolution of Class II furcation defects.
BACKGROUND:
Use of bone regeneration materials is becoming common in periodontal surgeries including furcation defects and the promising role of bioactive allograft materials has encouraged their presentation in different morphologic forms with their own advantages and disadvantages giving the operator ample of choices in his/her periodontal armamentarium.
MATERIALS AND METHODS:
A total of 28 patients with 40 Class II furcation defects were enrolled in the study and were randomly allocated to two groups with 20 sites in each group. Measurement of defects was done using clinical and cone beam computed tomography (CBCT) methods. The patients were followed-up at 6 months. Intergroup comparisons were done using Mann-Whitney U-test.
RESULTS:
There was no significance between group differences in clinical parameters and defect size at the baseline. After 6 months, particulate form showed a mean resolution of 50.48 ± 16.47% and 51.11 ± 9.48%, respectively for vertical defect and horizontal defect while putty form showed a mean resolution of 43.48 ± 9.33% and 42.88 ± 11.09%, respectively. Mean resolution in furcation width was 40.15 ± 13.00% for particulate form as compared with 36.27 ± 11.41% in putty form. Statistically, there was no significant difference between two groups except for the horizontal defect fill where PerioGlas showed statistically better results.
CONCLUSION:
Putty form was comparable to particulate form for resolution of Class II furcation defects.
AuthorsAsmita, Vivek Gupta, Vivek Kumar Bains, G P Singh, Rajesh Jhingran
JournalIndian journal of dental research : official publication of Indian Society for Dental Research (Indian J Dent Res) Vol. 25 Issue 2 Pg. 166-73 ( 2014) ISSN: 1998-3603 [Electronic] India
PMID24992845 (Publication Type: Comparative Study, Journal Article, Randomized Controlled Trial)
Chemical References
  • Bioglass
Topics
  • Ceramics
  • Cone-Beam Computed Tomography
  • Furcation Defects (surgery)
  • Humans
  • Mandible (surgery)

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: