HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Locking plate as a definitive external fixator for treating tibial fractures with compromised soft tissue envelop.

AbstractINTRODUCTION:
Tibial fractures with compromised soft tissue envelop may lead to significant complications. The optimal management of these injuries remains controversial. Recently, locking plate used as a definitive external fixator is attractive because it not only minimizes trauma to the soft tissues, but also overcomes the shortcomings of standard external fixators. The objective of this study was to evaluate the outcome of using locking plate as a definitive external fixator for treating tibial fractures with compromised soft tissue envelop.
PATIENTS AND METHODS:
A prospective series of 12 consecutive tibial fractures with compromised soft tissue envelop were treated using locking plate as a definitive external fixator. Of these patients, six were Gustilo and Anderson type IIIA, three were type II and three were closed fractures (AO/ASIF soft tissue injury classification IC4: 2, IC5: 1). Time to union, nonunion, malunion, leg shortening, range of motion and function for the knee and ankle, deep infection, pin tract infections were evaluated.
RESULTS:
The mean bone healing time was 37.8 weeks (range 20-56 weeks). Eventually, all of the fractures united. Most of the fractures healed in acceptable positions. There were no cases of deep infection. Pin tract infection was seen in 1 (8.3 %) patient, no loosening or failure of the external fixator was seen. At the most recent follow-up, the mean range of motion at the knee was extension 0° to flexion 135°, and the mean ankle range of motion was dorsi flexion 12° to plantar flexion 32°. All patients had excellent or good functional results and were fully weight bearing with a well-healed tibia at the final follow-up.
CONCLUSION:
The locking plate used as a definitive external fixator provided a high rate of union. The patients experienced a comfortable clinical course, excellent knee and ankle joint motion, satisfactory functional results and an acceptable complication rate. However, the stiffness of external locked plating is not clear, therefore, clinical recommendation on its practical use to reduce the risk of implant failure still need to be determined.
AuthorsXu-sheng Qiu, Han Yuan, Xin Zheng, Jun-fei Wang, Jin Xiong, Yi-xin Chen
JournalArchives of orthopaedic and trauma surgery (Arch Orthop Trauma Surg) Vol. 134 Issue 3 Pg. 383-8 (Mar 2014) ISSN: 1434-3916 [Electronic] Germany
PMID24362495 (Publication Type: Journal Article, Research Support, Non-U.S. Gov't)
Topics
  • Adult
  • Aged
  • Bone Plates
  • External Fixators
  • Female
  • Fracture Fixation (instrumentation, methods)
  • Humans
  • Male
  • Middle Aged
  • Prospective Studies
  • Range of Motion, Articular
  • Tibial Fractures (surgery)
  • Treatment Outcome
  • Weight-Bearing
  • Young Adult

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: